Page 42
Step 6:
When the auto focusing has completed the LCD panel will display the message
Auto Focusing Please Wait
Step 4.
Make sure that the
Auto Focus Probe
is located over
Solid Material
. i.e; that when the auto focus
button is pressed the probe will not pass through the grid bed.
Step 5.
Auto Focus
button on the control panel (Shown below), this will raise the material to contact
the auto focus probe which will in turn lower the material ensuring that the lens inside the head is at its
optimum distance a way from the material (2 inches).
Press the
The machine setup has now been completed.
Auto Focus
Probe
When the auto focusing is complete
0.0mm
will be displayed, pressing the
F1
button will return you back to
the main menu screen.