background image

16

5.4. Measurement of range to the last target

If a target to be measured is overlapped by close targets, the signals from which

come to  the  rangefinder,  and  there  is  no  object  within  the  transmitter  beam

behind the target (i.e. the reflected signal from this object does not  come to  the

rangefinder), then a range to  such  a target is  the  easiest to  be measured in  the

last target measurement mode (the 

mode).

  

Set the operating mode switch to the 

L

 position and make ranging according  to

5.2.

5.5. Switching-off

The handle of the power supply  switch  should  not  be left  in  the 

ON

 position

for a long time since in this case  the  battery is  quickly  discharged. That's  why

the rangefinder supply should be switched off on completion of rangings.

6. MAINTENANCE

6.1. General

It is prohibited to disassemble the rangefinder.

6.2. Operator's maintenance duties (preventive maintenance)

The  necessary  maintenance  of  the  rangefinder  includes  execution  of  the

following operations:

1)  in  case of  detection of  damages, faults  or  performance  degradation,  inform

the manufacturer;

2) in case of contamination, wipe the  optical  surfaces, the  housing,  the  control

handles of the rangefinder with the cloth from the Accessory set;

3) if the silica gel colour changes from blue  to  pink  (in  this  case the  silica  gel

is  saturated with  moisture),  replace the  silica  gel  in  the  desiccator  after  prior

heating the replacement silica gel from the Accessory set until it becomes blue;

4)  carry  out  charging  the  accumulator  battery  (when  the  battery  discharge

indicator lights (see Fig. 5).

Carry  out  charging  when  the 

ON 

supply  tumbler  is  switched  off  in    the

following manner:

- set the charged accumulator battery into the rangefinder;

- insert the charger into the socket;

- connect the charger to the rangefinder through the plug to connect the cable

  of external supply 

=12 

(see Fig. 2). In this case the (Charge) indicator on the

Содержание EG-LRF 20000

Страница 1: ...EG LRF 20000 technical description and instruction manual ...

Страница 2: ... can measure ranges from 60 to 20 000 m with an accuracy of 5 m The maximum range depends on a target size and shape as well as weather conditions and can exceed 20 000 m in case of good target visibility The solid state laser used in this EG LRF rangefinder is classified as 1 Class of laser hazard and its emission is eye safe for people being within the laser beam The EG LRF 20000 delivery set in...

Страница 3: ...3 Fig 1 EG LRF 20000 rangefinder set 1 Carrying case 2 Rangefinder 3 Accumulator battery 1 3 2 ...

Страница 4: ...mation on range 5 boresight eyepiece 6 digital display ocular 7 ON supply switch 8 external power supply and remote trigger plug 9 MIN RANGE minimum range gate handle 10 battery compartment lid 11 receiving and sighting channel objective 12 transmitting channel objective 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 5: ...he following items 1 Supply cable and cable to output information on range 2 Cloth to wipe optical surfaces 3 Silica gel to replace the wet one in the desiccator 2 5 Charger for accumulator batteries The AD 150 VD portable charger is designed to charge Ni Cd battery of 12 V voltage and capacity from 0 5 to 1 0 A h The charger is a stabilized DC source Technical characteristics of the AD 150 VD Mai...

Страница 6: ...es the time between these two pulses and transforms it into the information on range 3 2 Design and operation The rangefinder block diagram is given in Fig 3 The rangefinder consists of the following main parts the transmitting 11 12 13 14 15 and receiving 9 8 7 4 channels the boresight 5 6 7 8 9 the display and control unit 3 The rangefinder optical configuration Fig 4 provides formation of a las...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...ge measurement to the last target within the rangefinder transmitter beam is carried out When operating in the C mode the value of minimum range is shown on the digital display By the MIN RANGE handle a necessary value of minimum range is set within 40 4500 m 3 2 1 Rangefinder operation in ranging mode mode switch in F or L position When the ON switch is switched on the storage capacitor is gettin...

Страница 10: ...be changed from 40 m for the extreme counter clockwise position of the handle to 4500 m for the extreme clockwise position of the handle The accuracy of minimum range setting is 20 m When pressing the START button in the CONTROL mode the control range is measured to check the serviceability of the rangefinder timer In this case there is no laser pulse The START and STOP electrical pulses are forme...

Страница 11: ... a target gated out by the minimum range setting 0 3 5 0 0 M indicator c Digital display readings when the rangefinder detects a signal reflected from an object behind the measured target d Digital display readings when there is no start signal at the photoreceiver input 0 0 0 0 0 e Digital display readings when there is no signal reflected from the target Fig 5 Display of ranging results and rang...

Страница 12: ... of digital display LED indicators observed through eyepiece Multiple target 1 target displayed indica tion of more than 1 target registered Operating mode first last target Minimum range setting m 40 4500 Minimum range setting accuracy m 20 4 3 Sight Magnification 7 5 x Field of view 5 5 Objective diameter mm 43 Range of eyepiece dioptric setting 4 4 4 Power supply Built in battery NiCd 12 V 0 55...

Страница 13: ...sed before the green ready indicator lights measurement will be made with a delay until the green indicator lights 6 if the M indicator multiple target lights carefully examine the target area through the sight eyepiece to identify other targets see Fig 6 For positive identification of all targets the arrangement for minimum range setting can be additionally used as explained in 5 3 7 if the C ind...

Страница 14: ...range in the left eyepiece continuously rotating the MIN RANGE handle set a required value of minimum range set the MODE switch to the F position and measure the range to a target as explained in 5 2 Due to the fact that a portion of the transmitter beam is intercepted by objects in front of a target a signal from the target can be lower than the level of operation of the rangefinder receiver so w...

Страница 15: ...00 Target 3500 m There is a target behind the displayed one 4200 m and a target within the gate 2200 m F 3550 4200 Target 4200 m There is a target within the gate 3500 m L 60 4200 Target 4200 m There is a missed target 3500 m L 2250 4200 Target 4200 m There is a missed target 3500 m and a target within the gate 2200 m Fig 6 Example of ranging with multiple targets ...

Страница 16: ...ance duties preventive maintenance The necessary maintenance of the rangefinder includes execution of the following operations 1 in case of detection of damages faults or performance degradation inform the manufacturer 2 in case of contamination wipe the optical surfaces the housing the control handles of the rangefinder with the cloth from the Accessory set 3 if the silica gel colour changes from...

Страница 17: ... carry out training of the energy storage capacitor of the head supply unit Carry out training in the following manner a shift the supply tumbler of the rangefinder to the ON position b after 10 15 s press and release the start button c repeat the operations according to the clause b until the green readiness indicator on the digital indicator display lights see Fig 5 after that the rangefinder is...

Страница 18: ...the rangefinder to the computer by direct connection to the COM1 3F8h 9 pin port To operate the computer it is necessary connect the computer with the rangefinder by the cable to start the LRF EXE control program on the disk and switch on the rangefinder LRF EXE is the EG LRF rangefinder control program to provide communication of the rangefinder with the IBM PC having the WINDOWS XP operational s...

Страница 19: ...___ Name of parameter Permissible values Actual values Maximum range m no less 10 000 Minimum range m no more 60 Minimum range setting m 40 4500 Time of rangefinder readiness for measurement s no more 6 The product conforms with the technical requirements and is fit for operation Supplier Laseroptronix Enhagsslingan 23 187 409 Täby Sweden ...