3: Summary of CLI Commands
XPort Pro™ Command Reference
40
line level commands
Description
device boots and when the line is in command
mode.
<string> = text.
command mode signon message
binary <string>
Sets a binary sign-on message that is sent from the
serial port when the
device boots and when the line is in command
mode.
<string> = string that may contain binary
characters.
Within [] use binary decimal up to 255 or hex up to
0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial
string.
<milliseconds> = wait time.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default interface
Restores the default interface type to this line.
default parity
Restores the default of no parity.
default protocol
Restores the default protocol on the line.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on
the line.
gap timer <milliseconds>
Sets the gap timer in milliseconds. If some data has
been received, it will
be forwarded after this time since the last character.
interface rs232
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex
mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex
mode.
line <line>