4: Configuration Using Web-Manager
SDS1101/2101 User Guide
34
Modem Escape Sequence
Pass Through
Disable or enable the unit's ability to send the escape
sequence. The default is
Y
(Yes) (send the escape
sequence).
Connect Mode: Active Connection
Active Connect
Select
None
(default) to disable
Active Connect
. Otherwise,
indicate the connection type from the drop-down list:
With Any Character:
Attempts to connect when any
character is received from the serial port.
With Active Mdm Ctrl In:
Accepts external connection
requests only when the
Modem Control In
input is
asserted.
With Start Character:
Attempts to connect when it
receives a specific start character from the serial port.
The default start character is carriage return.
Manual Connection:
Attempts to connect when
directed by a command string received from the serial
port.
Auto Start:
Automatically connects to the remote IP
address and port after booting up.
Start Character
If Active Connect is set to With Start Character, enter the start
character in this field. The default setting is
0D
.
Modem Mode
Indicates the on-screen response type when in Modem Mode (if
Modem Mode is enabled). The default setting is
None
.
Show IP Address After
Ring
Indicates whether to display the remote IP address upon
connection. The default setting is
Yes
.
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment for active
connect
Select to auto-increment the local port number for new
outgoing connections. The range of auto-incremented port
numbers is 50,000 to 59,999 and loops back to the beginning
when the maximum range is reached. Disabled by default.
Remote Port
Enter the remote port number.
Remote Host
Enter the IP address of the remote device.
Common Options
Telnet Com Port Cntrl
This field is available for configuration only when
Active
Connect
is set to
None
. Select
Enable
to permit Telnet
communication to the SDS unit. The
Telnet Com Port Cntrl
feature is used in conjunction with the Com Port Redirector
(CPR) utility. (See the CPR online Help for details.)
Terminal Name
This field is available for configuration only when
Telnet Com
Port Cntrl
is set to
Enable
.