4: Configuration Using Web-Manager
SDS1101/2101 User Guide
28
Monitor Mode @ Bootup
Select Disable to disable entry into the monitor mode using
the yyy or xx1 key sequence at startup. This field prevents the
unit from entering monitor mode by interpreting the stream of
characters that are received during the device server's
initialization at startup. The default setting is
Enable
.
CPU Performance Mode
(SDS2101 Only)
Select the
SDS2101's
performance mode. Higher
performance settings require more energy.
Low
is 26 Mhz.
Regular
is 48 Mhz;
High
is 88 Mhz. The default is
Regular
.
HTTP Server Port
This option allows the configuration of the web server port
number. The valid range is
1-65535
. The default setting is
80
.
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical
packet size a network can transmit for TCP and UDP. Enter
between 512 and 1400 bytes. The default setting is
1400
bytes
.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Host List Configuration
The SDS scrolls through the host list until it connects to a device listed in the host list
table. After a successful connection, the unit stops trying to connect to any others. If
this connection fails, the unit continues to scroll through the table until the next
successful connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry
contains an IP address and a port number.
Note:
The host list is disabled for Manual and Modem Mode. The unit does
not accept a data connection from a remote device when the hostlist option is
enabled.
To configure the host list:
1. On the main menu, click
Hostlist
.
Содержание SDS1101
Страница 1: ...Part Number 900 451 Revision C February 2010 SDS1101 2101 User Guide ...
Страница 50: ...7 Setup Mode Channel Configuration SDS1101 2101 User Guide 50 Figure 7 2 Hostlist Option ...
Страница 96: ...SDS1101 2101 User Guide 96 TFTP 66 Troubleshooting 9 71 UDP settings 35 Warranty 91 Web Manager 23 ...