8: Setup Mode: Advanced Settings
SDS1101/2101 User Guide
60
sequences (only during the bootup sequence). The default for Disable Monitor Mode
at bootup is
N
(No). (See
10: Monitor Mode
.)
Monitor Mode @ bootup : enabled
HTTP Port Number
This option allows the configuration of the web server port number. The valid range is
1-65535
. The default HTTP port number is
80
.
HTTP Port Number : (80) ? _
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size a network
can transmit for TCP and UDP. Enter between
512
and
1400
bytes. The default
setting is
1400
bytes.
MTU Size: (1400) ? _
Enable alternate MAC
If necessary, enable the alternate MAC address (if specified in the OEM setup
record). The default setting is
N
(No).
Enable alternate MAC (N) ? _
Ethernet connection type
The SDS allows for the Ethernet speed and duplex to be manually configured. Enter
0
for auto-negotiation (default). To select the speed and duplex, enter one of the
following:
2
(10Mbit/half duplex),
3
(10Mbit/full duplex),
4
(100Mbit/half duplex), or
5
(100Mbit/full duplex).
Ethernet connection type: (0) ? _
Security Settings (Option 6)
You can change security settings by means of Telnet or serial connections only, not
on the Web-Manager.
We recommend that you set security over the dedicated
network or over the serial setup to prevent eavesdropping.
Caution:
Disabling both Telnet Setup and Port 77FE will prevent users
from accessing the setup menu from the network. Disabling Port 77FE
also disables the Web from configuring the device.
Select
6
to configure security settings.