Ports
RS-485 Configuration
8-15
The example in Figure 8-37 can be visualized as:
x x x xxx xx (data) x x xx xxxxxxxx xx xxxx xx xxxx
|-----------------------------------------------------|
150 milliseconds transmit packet
Another option is to set a one- or two-character trigger that will cause the SCS to transmit the data. You can
also specify whether the trigger characters will be sent to the host as part of the serial data or whether they
should be discarded (the default). For example, the following commands will cause the accumulated serial
data to transmit as soon as the “Z” character is detected in the data stream and to send the matched character
(“Z”) to the host as part of that data.
Figure 8-38:
Transmitting Serial Data with a Character Trigger
The example in Figure 8-38 can be visualized as:
x x x xxx xx (data) x x xx xxxxxxxx xx xxx Z xx xxxx
|-----------------------------------------------------|
transmit packet
The
Set/Define Ports Datasend
command is also discussed on page 12-66.
8.9.8 Restoring Default Port Settings
To restore all ports to their default settings, use the
Purge Port
command. Use caution with this command;
any changes that you’ve made with the Set and Define commands will be erased.
Figure 8-39:
Restoring Default Port Settings
If the Purge Port command cannot be used (for example, if authentication has been defined on all ports), the
settings can only be restored by using the Boot Configuration Program. See your
User Guide
for details.
8.10 RS-485 Configuration
Note:
This section only applies to the SCS200.
While the SCS serial ports are is initially configured for RS-232 networking, they can also be configured
for RS-485 networking. The RS-485 standard allows a serial connection to be shared like a “party line.” As
many as 32 devices can share the multidrop network. Typically, one device is the master and the other
devices are slaves. There are a few important things to note about RS-485 networking with the SCS.
The SCS can be used in either two-wire or four-wire mode. Refer to the following sections to
determine which mode to use.
The maximum RS-485 network cabling length (without repeaters) is 4,000 feet. Lantronix
recommends the use of shielded twisted-pair cabling.
Local>> DEFINE PORT 2 DATASEND CHARACTER Z
Local>> DEFINE PORT 2 DATASEND SAVE 1
Local>> PURGE PORT 2