7: Line and Tunnel Settings
PremierWave® EN Embedded System on Module User Guide
68
When attached to a Linux host, the USB-CDC-ACM connection will automatically be configured,
assuming the Linux host is configured for USB host operation and the "cdc_acm" driver is
available. Once recognized, the cdc_acm driver will configure a standard serial port in the /dev/
ttyACMx series, where x is a number 0, 1, 2, 3, etc.
Caution:
Under Linux, if the /dev/ttyACMx device is in use when the PremierWave
EN unit is rebooted, some terminal programs under Linux will
automatically disconnect while others will not. If a terminal program
does not disconnect automatically, when the PremierWave EN device
comes back up, the CDC-ACM connection will be enumerated to a
different /dev/ttyACMx device.
Line Settings
Note:
The following section describes the steps to configure Line 1; these steps apply to
other line instances of the device.
To Configure Line Settings
Using Web Manager
To configure Line 1, click
Line
in the menu and select
Line 1 ->
Configuration
.
Using the CLI
To view Line statistics:
enable -> line 1, show statistics
Using XML
Include in your file:
<statusgroup name=”line” instance=”1”>
The Line Settings allow configuration of the serial lines (ports).
Table 7-1 Line Configuration Settings
Line Settings
Description
Name
Enter a name or short description for the line, if desired. By default, there is
no name specified. A name that contains white space must be quoted.
Interface
Set the interface type for the Line. The default is
RS232
, and
USB-CDC-ACM
for Line 3.
Choices are:
RS232but may
RS485 Full-Duplex
RS485 Half-Duplex
Termination
Select to
Enable
or
Disable
Line Termination. The default is
Disable
.
Note:
This setting is only relevant for Interface type RS485 Half-Duplex.
State
Select to enable or disable the operational state of the Line. The default is
Enabled
.