![Lantronix PremierWave EN Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/lantronix/premierwave-en/premierwave-en_user-manual_675657049.webp)
6: Line and Tunnel Settings
PremierWave EN User Guide
49
To Configure Tunnel Connect Mode Settings
Using Web Manager
To configure the Connect Mode for a specific tunnel, click
Tunnel
in the menu and select
Tunnel 1 -> Connect Mode
.
Using the CLI
To enter the Tunnel 1 Connect Mode command level:
enable -> tunnel 1 -> connect
Using XML
Include in your file:
<configgroup name="tunnel connect" instance="1">
Disconnect Mode
Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection
that may be established. If any of these conditions are selected but do not occur and the network
disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none
of these conditions are selected, a closure from the network is taken as a disconnect.
Block Serial
Set whether Block Serial is enabled for debugging purposes. Choices are:
Enabled
= If Enabled, incoming characters from the Serial Line will not be
forwarded to the network. Instead, they will be buffered and will eventually
flow off the Serial Line if hardware or software flow control is configured.
Disabled
= this is the default setting; incoming characters from the Serial Line
are sent on into the network. Any buffered characters are sent first.
Block Network
Set whether Block Network is enabled for debugging purposes. Choices are:
Enabled
= If Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will eventually
flow off the network side.
Disabled
= this is the default setting; incoming characters from the network
are sent on into the Serial Line. Any buffered characters are sent first.
Email on Connect
Select an email profile number to which an email notification will be sent upon
the establishment of an accept mode tunnel.
Email on Disconnect
Select an email profile number to which an email notification will be sent upon
the disconnection of an accept mode tunnel.
CP Output
Enter the CP Output Group whose value should change when a connection is
established and dropped. Connection Value specifies the value to set the CP
Group to when a connection is established. Disconnection Value specifies the
value to set the CP Group to when the connection is closed. To display the
“Connection Value” and “Disconnection Value”, first enter a “CP Output Group”,
then click outside that field.
Tunnel Connect Mode
Settings (continued)
Description