![Lantronix PremierWave EN Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/lantronix/premierwave-en/premierwave-en_user-manual_675657043.webp)
6: Line and Tunnel Settings
PremierWave EN User Guide
43
To enter Line 1 command level:
enable -> line 1
Using XML
Include in your file:
<configgroup name="line" instance="1">
Include in your file:
<configgroup name="serial command mode" instance="1">
To View Line Statistics
Using Web Manager
To view statistics for a specific line, click
Line
in the menu and select
Line 1 ->
Statistics
.
Using the CLI
To view Line statistics:
enable -> line 1, show statistics
Using XML
Include in your file:
<statusgroup name=”line” instance=”1”>
Tunnel Settings
Tunneling allows serial devices to communicate over a network, without “being aware” of the
devices which establish the network connection between them. Tunneling parameters are
configured using the
Tunnel
menu and submenus under
Setup
. The Tunnel settings allow you to
configure how the Serial-Network tunneling operates. Tunneling is available on all serial lines.
The connections on one serial line are separate from those on another serial port.
Note:
The following section describes the steps to view and configure Tunnel 1 settings;
these steps apply to other tunnel instances of the device.
Serial Settings
These serial settings for the tunnel apply to the Serial Line interface. The Line Settings and
Protocol are displayed for informational purposes and must be configured from the Line settings.
Table 6-3 Tunnel Serial Settings
Tunnel Serial
Settings
Description
Line Settings
Line Settings information here is display only. Go to the section,
To Configure
Line Settings
to modify these settings.
Protocol
Protocol information here is display only. Go to the section,
To Configure
Line Settings