15: Maintenance
EMG™ Edge Management Gateway User Guide
337
2. Enter the following:
Internal Temperature
Site Information
EMG Firmware
Note:
The non-active boot bank is updated during the firmware update, without requiring
a reboot. The configuration on the current boot bank may optionally be copied to the non-
active boot bank during the firmware update.
Reboot
Select this option to reboot the EMG immediately. The default is
No
.
Shutdown
Select this option to shut down the EMG unit. The default is
No
.
Current
Displays current temperature.
Low
Sets the acceptable minimum for the internal temperature of the EMG. If the
temperature changes to be outside of this range, the EMG will issue an SNMP
trap.
High
Sets the acceptable maximum for the internal temperature of the EMG unit. If the
temperature changes to be outside of this range, the EMG unit will issue an
SNMP trap.
Calibrate Offset
An offset for calibrating the internal temperature of the EMG unit. The offset will be
applied one hour after setting the calibration value. Zeroing the offset will take
effect immediately and will cancel any current and/or pending calibration.
Data Center Rack Row
Set these fields to define the rack row the EMG unit is located within a large data
center. The default for these fields is 1.
Data Center Rack
Cluster
Set these fields to define the rack cluster the EMG is located within a large data
center. The default for these fields is 1.
Data Center Rack
Set these fields to define the rack the EMG unit is located within a large data
center. The default for these fields is 1.
Site Tag
Tag or description used to identify the location or some other attribute of the EMG.
Current Version
Displays the current firmware version.
Clear FW Update Log
(checkbox)
Clears the contents of the Firmware Update log file.
Firmware Update Log
(link)
To view a log of all prior firmware updates, click the
Firmware Update Log
link.
Update Firmware
To update the EMG firmware, select the checkbox. If you select this option, the
EMG unit reboots after you apply the update. The first time boot for each bank
may take up to 5 minutes. Subsequent boot times will be approximately 2
minutes.
To view a log of all prior firmware updates, click the
Firmware Update Log
link.
Firmware Filename
The name of the firmware update file downloaded from the Lantronix web site.
Key
A key for validating the firmware file. The key is provided with the firmware file
(32 hex characters).
Содержание EMG 7500
Страница 1: ...Part Number PMD 00008 Revision C April 2020 EMG Edge Management Gateway User Guide EMG 8500 EMG 7500 ...
Страница 82: ...7 Networking EMG Edge Management Gateway User Guide 82 Figure 7 2 Network Network Settings 2 of 2 ...
Страница 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Страница 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Страница 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Страница 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...