8: Services
EMG™ Edge Management Gateway User Guide
172
Device ID is invalid, the Registration Host name cannot be resolved, or the Registration Host
is not reachable. Once registration is successful,
Status of Client
will display
Registered
with
the date and time of registration. Note that the Registered date/time displayed in the EMG
status may be different from the registered date/time shown in the ConsoleFlow web UI. The
EMG registered date/time is the most recent date and time that the EMG registered with the
ConsoleFlow server. The registered date and time shown in the ConsoleFlow web UI is the
first time that the EMG ever registered with the ConsoleFlow server.
2. Telemetry
After registration, the client will connect to the Telemetry Host (the hostname is provided
during registration) and perform a telemetry handshake. This handshake may request that the
client publish a set of statistics at regular intervals. If a telemetry handshake is successful,
Status of Client
will display
Telemetry Handshake
with the date and time of the handshake.
Each time telemetry statistics are published,
Status of Client
will display
Telemetry
Statistics
with the date and time the statistics were sent.
3. Messages and Status Updates
After the telemetry handshake, the client will connect to the
Messaging Host
to receive
messages and publish status updates. If the connection fails, the client will wait 5 seconds and
retry. The connection may fail if the Messaging Host name cannot be resolved, or the
Messaging Host is not reachable. Once the connection is successful, Status of Client will
display Messaging connected with the date and time the connection was established.
The client publishes status update messages (changes to device attributes) at the interval
defined by Interval between Status Updates. Each time a status update is published,
Status
of Client
will display
Status
with the date and time the status was sent. The client also
accepts command messages from the ConsoleFlow server to perform actions, such as reboot
or shutdown. Each time a message is received,
Status of Client
will display
Message
received
with the date and time the message was received.
4. Firmware and Configuration Updates
The client checks for firmware and configuration updates at the interval defined by
Interval
between FW and Config Checks
. When the client checks for firmware or configuration
updates,
Status of Client
will display
Checked for Content
with the date and time the check
was performed. If a firmware update is found, it will be applied to the alternate (non-active)
boot bank, and Status of Client will display
Firmware updated
with the date and time the
firmware was updated. If a configuration update is found, it will be applied to the current boot
bank, and
Status of Client
will display
Configuration restored
with the date and time the
configuration was restored.
5. Web Terminal Connections
ConsoleFlow allows users to make secure, encrypted connections via SSL/TLS to the CLI and
device ports. This connection opens a web terminal session in a new browser tab in the
ConsoleFlow UI. The connection is terminated when the user closes the web terminal session.
When a Web Terminal connection is initiated,
Status of Client
will display
Web Terminal
Connection
with the date and time the connection was initiated. Web Terminal connections
are also displayed in the Connections list in the console manager web UI and CLI. Currently
paste in Web Terminal Sessions is limited to 500 lines. Some browsers may not support
pasting more than 500 lines, as this may cause the Web Terminal session to be terminated.
6. Performance Monitoring Probes and Custom Scripts
ConsoleFlow allows users to create Performance Monitoring Probes and Custom Scripts to
run on the console manager. When the client starts, it will request all probes and scripts that
are defined to run on the console manager. The status of the probes and scripts is displayed in
Содержание EMG 7500
Страница 1: ...Part Number PMD 00008 Revision C April 2020 EMG Edge Management Gateway User Guide EMG 8500 EMG 7500 ...
Страница 82: ...7 Networking EMG Edge Management Gateway User Guide 82 Figure 7 2 Network Network Settings 2 of 2 ...
Страница 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Страница 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Страница 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Страница 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...