14: User Authentication
EMG™ Edge Management Gateway User Guide
326
Figure 14-12 Current Host Keys
2. View or enter the following:
Reset to Default Host
Key
Select the
All Keys
checkbox to reset all default key(s), or select one or more
checkboxes to reset defaults for
RSA
, or
DSA
keys. All checkboxes are
unselected by default.
Import Host Key
To import a site-specific host key, select the checkbox. Unselected by default.
Type
From the drop-down list, select the type of host key to import.
Import via
From the drop-down list, select the method of importing the host key (SCP or
SFTP). The default is
SFTP
.
Public Key Filename
Filename of the public host key.
Private Key Filename
Filename of the private host key.
Host
Host name or IPaddress of the host from which to import the key.