5: Commands and Levels
EDS1100/2100 Command Reference
129
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been received,
it will
be forwarded after this time since the last character.
interface rs232
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level.
<line> = number of the line (serial port) to be configured.
lpd
<line>
Enters the configure lpd level.
<line> = number of the line (lpd serial port) to be configured.
name
<text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode serial string
Prevents the user-defined serial boot string from being used to
enter
command mode in the CLI.
no command mode signon message Clears the signon message displayed at boot time and when
entering
command mode.
no gap timer
Removes the gap timer, so forwarding depends on the line speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.
ppp
<line>
Enters the serial line PPP level.
protocol lpd
Applies Line Printer Daemon (LPD) protocol on the line.
protocol lpd or tunnel
Applies LPD or tunnel protocol on the line.
protocol modbus ascii
Applies Modbus ASCII protocol on the line.
protocol modbus rtu
Applies Modbus RTU protocol on the line.
protocol none
Uses no protocol on the line.
protocol ppp
Applies point-to-point protocol (PPP) on the line.
protocol tunnel
Applies tunnel protocol on the line.
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current CLI