5: Commands and Levels
EDS1100/2100 Command Reference
127
enter
command mode in the CLI.
no command mode signon message Clears the signon message displayed at boot time and when
entering
command mode.
no gap timer
Removes the gap timer, so forwarding depends on the line speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.
ppp
<line>
Enters the serial line PPP level.
protocol lpd
Applies Line Printer Daemon (LPD) protocol on the line.
protocol lpd or tunnel
Applies LPD or tunnel protocol on the line.
protocol modbus ascii
Applies Modbus ASCII protocol on the line.
protocol modbus rtu
Applies Modbus RTU protocol on the line.
protocol none
Uses no protocol on the line.
protocol ppp
Applies point-to-point protocol (PPP) on the line.
protocol tunnel
Applies tunnel protocol on the line.
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current CLI
session.
show line
Displays the current configuration.
show statistics
Shows the line statistics.
state disable
Disables the line so data cannot be sent/received.
state enable
Enables the line so data can be sent/received.
stop bits 1
Uses one stop bit after data on the line.
stop bits 2
Uses two stop bits after data on the line.
terminal
<line>
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be configured.
terminal network
Enters the configure-terminal level for the network.
termination disable
Refrains from terminating the line.
termination enable
Enables 120 ohm line termination in RS485 half-duplex mode.
threshold
<bytes>
Sets the threshold in bytes. After this many bytes are received,
they are
forwarded without delay.
tunnel
<line>
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be configured.
write
Stores the current configuration in permanent memory.
xoff char
<control>
Sets the xoff character for use with software flow control on this
line.
The character may be input as text, control, decimal, or hex.
A control character has the form <control>C.
A decimal value character has the form \99.
A hex value character has the form 0xFF.