background image

 

6

 

IMPORTANT READ 

FIRST 

IMPORTANT

 

CAUTION 

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY.  IF SPILLS 
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR 
FALLS. 

 

NOTICE 

Once the griddle temperature set point has been changed, it will heat to 
that setting each time the griddle is turned on. Refer to “Changing the 
Griddle Temperature. 

 

NOTICE 

In order for the Day Part feature to work properly, you must set up at least 
two day parts. If only one day part is set, the control will use this setting as 
the default temperature setting.   

 

WARNING 

KEEP WATER AND SOLUTIONS OUT OF CONTROLS.  NEVER SPRAY OR 
HOSE CONTROL CONSOLE. 

 

CAUTION 

MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS 
MEMBRANES AND CLOTHING.  PRECAUTIONS SHOULD BE TAKEN TO 
WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE 
CLOTHING.  CAREFULLY READ THE WARNING AND FOLLOW THE 
DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. 

 

NOTICE 

Never leave a chlorine sanitizer in contact with stainless steel surfaces 
longer than 10 minutes.  Longer contact can cause corrosion. 

 

NOTICE 

Service on this or any other Lang Manufacturing appliance must be 
performed by qualified personnel only. Consult your authorized service 
agent directory or call the factory at 1-800-807-9054, or visit our website at 

WWW.STAR-MFG.COM

  For the service agent nearest you. 

 

WARNING 

HIGH VOLTAGE IS PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS 
PLUGGED / WIRED INTO A LIVE RECEPTACLE.  BEFORE REPLACING 
ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER 
SUPPLY. 

 

CAUTION 

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY 
LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY 
INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND 
WILL VOID ALL WARRANTIES. 

 

IMPORTANT 
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE 
"ANSI Z223.1/NFPA 54 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES 
AND REGULATIONS.  IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH 
THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR 
CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE 
APPLICABLE.

 

 

Содержание 224Z

Страница 1: ...al 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W359 Ph 314 781 2777 Fax 314 781 2714 Rev C WWW STAR MFG COM October 29 2007 Installation Operation and Maintenance Instructions Gas Griddle Mo...

Страница 2: ...RK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is on top of the...

Страница 3: ...SE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT THE USER SMELLS GAS THIS INF...

Страница 4: ...PAGE Safety 2 Table Of Contents 4 Equipment Description 7 Unpacking 9 Installation 10 Initial Start Up 13 Operation 14 Cleaning Procedures 19 Troubleshooting 20 Exploded View 22 Parts List 23 Wiring D...

Страница 5: ...components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards WARNING THIS APPLIANCE IS EQUI...

Страница 6: ...r in contact with stainless steel surfaces longer than 10 minutes Longer contact can cause corrosion NOTICE Service on this or any other Lang Manufacturing appliance must be performed by qualified per...

Страница 7: ...can be set between 400 F 200 C and 550 F 288 C in 5 increments The minimum temperature value can be set between 100 F and 175 F in 5 increments The controls reaction to changes in temperature is also...

Страница 8: ...PLIED 272Z 72 INCHES 162 000 162 000 ONE 3 4 NPT 115 VOLT 2 SUPPLIED SPECIFICATIONS AND INFORMATION GRILL SURFACE OVERALL CLEARANCE FROM NON COMBUSTIBLE SURFACES MODEL NUMBER WIDTH DEPTH SQUARE INCHES...

Страница 9: ...nded location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crating The griddle will arrive completel...

Страница 10: ...contact is made with the threaded nut at the top of the receiver tube Screw the leg counter clockwise until it is hand tight Tighten the setscrew on the receiver tube one per leg WARNING THIS APPLIANC...

Страница 11: ...to the manifold The pressure in the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with the appliance operating at full fire A 1 8 inch NPT...

Страница 12: ...ody 10 Insert the new spring from the conversion kit and install the adjustment screw over it 11 Place the regulator pressure range sticker over the existing pressure range sticker 12 Place caution st...

Страница 13: ...enter a lock out situation and the controller must be cycled off and then back on Once the burners ignite the griddle will automatically preheat the griddle to its default temperature of 125 F 52 This...

Страница 14: ...eter and or return to normal operation Starting the Griddle Press the Power button The control will conduct a self test then display Control ready At this time the ignition sequence will begin Each bu...

Страница 15: ...ow buttons for five seconds If a user access code as been set the display will prompt for the access code now If not it will prompt for an L or R arrow button this will scroll through one of ten Manag...

Страница 16: ...ER If EDIT is selected and no Day Parts currently exist the control asks if a new Day Parts is to be added Use the UP or DOWN to toggle between YES and NO then press ENTER If YES is selected the contr...

Страница 17: ...an unsafe condition may exist Alarm Description Test Slow Warm Up Griddle takes to long to get to operating temperature Verify Main Burner ignition Spark Gap Spark Module Wiring between Spark Module a...

Страница 18: ...e Left arrow Down arrow Enter Once code is confirmed press Enter to save Reset Factory Defaults This setting when activated will reset all settings back to the configuration that left the factory It m...

Страница 19: ...he griddle with a thin film of oil to prevent rusting Clean the exterior of the appliance with hot water and a mild detergent to maintain a gleaming appearance Re season the griddle plate after each c...

Страница 20: ...orrecting the problem contact the nearest Lang service representative or Star Manufacturing International Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the...

Страница 21: ...ections sparks but does not light Failed Probe Griddle Overloading Verify Main Burner ignition Verify Gas Pressure Verify Temperature Probe operation Review Griddle Loading Controller prompts Section...

Страница 22: ...iption 141 701 Wire Harness 1 GG Short harness plugs on the module works in lanes 3 and 4 141 701 Wire Harness 2 GG Middleharness plugs on the module works in lanes 2 and 5 141 703 Wire Harness 3 GG L...

Страница 23: ...1 MANIFOLD ASSY 2 224Z NAT ZC LP 22 K9 141 156 3 2 VALVE SHIELD 224Z NAT ZC LP 23 2V 80502 04 2 SOLENOID VALVE 120VAC 1 2PIPE 224Z NAT ZC LP 24 K9 141 156 1 2 VALVE MOUNT BASE 224Z NAT ZC LP 25 K9 141...

Страница 24: ...Z 18 K9 141 181 3 BAFFLE UNDER BURNER 236Z 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 236Z 21 K9 141 157 3 1 MANIFOLD ASSY 3 236Z 22 K9 141 156 3 3 VALVE SHIELD 236Z 23 2V 80502 04 3 SOLENOID VALVE 120VAC...

Страница 25: ...248Z NAT 248 NATSC 248Z LPSC 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 248Z NAT 248 NATSC 2V 80501 05 1 GAS REG 3 4X3 4 CLS II 248Z LPSC 21 K9 141 157 4 1 MANIFOLD ASSY 4 248Z 22 K9 141 156 3 4 VALVE SHI...

Страница 26: ...2V 80501 04 1 GAS REG 3 4X3 4 CLS I 260Z 21 K9 141 157 5 1 MANIFOLD ASSY 5 260Z 22 K9 141 156 3 5 VALVE SHIELD 260Z 23 2V 80502 04 5 SOLENOID VALVE 120VAC 1 2PIPE 260Z 24 K9 141 156 1 5 VALVE MOUNT BA...

Страница 27: ...TBE UNON 3 8CC 1 2 272Z 27 2C 20102 12 12 SCRW PHD ST 10 32X3 8 PLTD T23 272Z 28 K9 141 152 6 SPARK MODULE MOUNT 272Z 29 2C 20102 04 12 SCRW PHD ST 8 32X 5 PLTD 272Z 30 2J 80300 17 6 SPRK IGN CNTRL 14...

Страница 28: ...7 6 5 4 3 2 1 SPARK MODULE SEC 1 SEC 2 POWER IN L1 N TEMPERATURE CONROLLER HEAT OUT SEC 3 SEC 4 SEC 5 SEC 6 SEC 7 SEC 8 1 2 3 4 5 6 7 8 VIEW FROM FRONT OF BOARD SPARK SENSE VALVE SECTION ONE SHOWN ALL...