background image

 

10

 

Installation

 

WARNING 

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED 
TO WORK WITH PLUMBING.  IMPROPER INSTALLATION CAN CAUSE INJURY 
TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.  UNIT MUST BE 
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES. 

 

NOTICE 

The data label is located behind the front panels on the inside face of each 
body side.  The English label is on the left; the French language label is on 
right. The griddle serial number, gas specifications, and clearance 
specifications are on the data plate.  This information should be carefully read 
and understood before proceeding with the installation. 

 

NOTICE 

The installation of any components such as a vent hood, grease extractors, 
fire extinguisher systems, must conform to their applicable National, State 
and locally recognized installation standards. 

 

Leg Installation 

The legs are installed by sliding the threaded ends of the legs into the leg 
receiver tubes located in each corner of the griddle.   
Slide the leg up until contact is made with the threaded nut at the top of the 
receiver tube. Screw the leg counter-clockwise until it is hand tight.   
Tighten the setscrew on the receiver tube (one per leg).

 

 

WARNING 

THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG FOR 
YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED 
DIRECTLY INTO A PROPERLY GROUNDED 3-PRONG RECEPTACLE.   DO 
NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE PLUG. 

 

Electrical Connection 

The electrical connection must be made in accordance with local codes or in 
the absence of local codes with NFPA No. 70, latest edition (in Canada use: 
CAS STD. C22.1). 
The electrical service is provided by a cord and plug located at the back of the 
griddle slight off center and adjacent to the gas connection. 
Each griddle requires a 115-volt, 2 amp grounded supply

.

 

 

NOTICE 

When this appliance is installed with casters, it must be installed with the casters 
supplied, a connector complying with either ANSI Z21.69 

 CSA 6.16 and a quick-

disconnect device complying with ANSI Z21.41 

 CSA 6.9.  It must also be installed with 

restraining means to guard against transmission of strain to the connector as specified 
in the appliance manufactures instructions.

 

Содержание 224Z

Страница 1: ...al 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W359 Ph 314 781 2777 Fax 314 781 2714 Rev C WWW STAR MFG COM October 29 2007 Installation Operation and Maintenance Instructions Gas Griddle Mo...

Страница 2: ...RK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is on top of the...

Страница 3: ...SE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT THE USER SMELLS GAS THIS INF...

Страница 4: ...PAGE Safety 2 Table Of Contents 4 Equipment Description 7 Unpacking 9 Installation 10 Initial Start Up 13 Operation 14 Cleaning Procedures 19 Troubleshooting 20 Exploded View 22 Parts List 23 Wiring D...

Страница 5: ...components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards WARNING THIS APPLIANCE IS EQUI...

Страница 6: ...r in contact with stainless steel surfaces longer than 10 minutes Longer contact can cause corrosion NOTICE Service on this or any other Lang Manufacturing appliance must be performed by qualified per...

Страница 7: ...can be set between 400 F 200 C and 550 F 288 C in 5 increments The minimum temperature value can be set between 100 F and 175 F in 5 increments The controls reaction to changes in temperature is also...

Страница 8: ...PLIED 272Z 72 INCHES 162 000 162 000 ONE 3 4 NPT 115 VOLT 2 SUPPLIED SPECIFICATIONS AND INFORMATION GRILL SURFACE OVERALL CLEARANCE FROM NON COMBUSTIBLE SURFACES MODEL NUMBER WIDTH DEPTH SQUARE INCHES...

Страница 9: ...nded location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crating The griddle will arrive completel...

Страница 10: ...contact is made with the threaded nut at the top of the receiver tube Screw the leg counter clockwise until it is hand tight Tighten the setscrew on the receiver tube one per leg WARNING THIS APPLIANC...

Страница 11: ...to the manifold The pressure in the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with the appliance operating at full fire A 1 8 inch NPT...

Страница 12: ...ody 10 Insert the new spring from the conversion kit and install the adjustment screw over it 11 Place the regulator pressure range sticker over the existing pressure range sticker 12 Place caution st...

Страница 13: ...enter a lock out situation and the controller must be cycled off and then back on Once the burners ignite the griddle will automatically preheat the griddle to its default temperature of 125 F 52 This...

Страница 14: ...eter and or return to normal operation Starting the Griddle Press the Power button The control will conduct a self test then display Control ready At this time the ignition sequence will begin Each bu...

Страница 15: ...ow buttons for five seconds If a user access code as been set the display will prompt for the access code now If not it will prompt for an L or R arrow button this will scroll through one of ten Manag...

Страница 16: ...ER If EDIT is selected and no Day Parts currently exist the control asks if a new Day Parts is to be added Use the UP or DOWN to toggle between YES and NO then press ENTER If YES is selected the contr...

Страница 17: ...an unsafe condition may exist Alarm Description Test Slow Warm Up Griddle takes to long to get to operating temperature Verify Main Burner ignition Spark Gap Spark Module Wiring between Spark Module a...

Страница 18: ...e Left arrow Down arrow Enter Once code is confirmed press Enter to save Reset Factory Defaults This setting when activated will reset all settings back to the configuration that left the factory It m...

Страница 19: ...he griddle with a thin film of oil to prevent rusting Clean the exterior of the appliance with hot water and a mild detergent to maintain a gleaming appearance Re season the griddle plate after each c...

Страница 20: ...orrecting the problem contact the nearest Lang service representative or Star Manufacturing International Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the...

Страница 21: ...ections sparks but does not light Failed Probe Griddle Overloading Verify Main Burner ignition Verify Gas Pressure Verify Temperature Probe operation Review Griddle Loading Controller prompts Section...

Страница 22: ...iption 141 701 Wire Harness 1 GG Short harness plugs on the module works in lanes 3 and 4 141 701 Wire Harness 2 GG Middleharness plugs on the module works in lanes 2 and 5 141 703 Wire Harness 3 GG L...

Страница 23: ...1 MANIFOLD ASSY 2 224Z NAT ZC LP 22 K9 141 156 3 2 VALVE SHIELD 224Z NAT ZC LP 23 2V 80502 04 2 SOLENOID VALVE 120VAC 1 2PIPE 224Z NAT ZC LP 24 K9 141 156 1 2 VALVE MOUNT BASE 224Z NAT ZC LP 25 K9 141...

Страница 24: ...Z 18 K9 141 181 3 BAFFLE UNDER BURNER 236Z 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 236Z 21 K9 141 157 3 1 MANIFOLD ASSY 3 236Z 22 K9 141 156 3 3 VALVE SHIELD 236Z 23 2V 80502 04 3 SOLENOID VALVE 120VAC...

Страница 25: ...248Z NAT 248 NATSC 248Z LPSC 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 248Z NAT 248 NATSC 2V 80501 05 1 GAS REG 3 4X3 4 CLS II 248Z LPSC 21 K9 141 157 4 1 MANIFOLD ASSY 4 248Z 22 K9 141 156 3 4 VALVE SHI...

Страница 26: ...2V 80501 04 1 GAS REG 3 4X3 4 CLS I 260Z 21 K9 141 157 5 1 MANIFOLD ASSY 5 260Z 22 K9 141 156 3 5 VALVE SHIELD 260Z 23 2V 80502 04 5 SOLENOID VALVE 120VAC 1 2PIPE 260Z 24 K9 141 156 1 5 VALVE MOUNT BA...

Страница 27: ...TBE UNON 3 8CC 1 2 272Z 27 2C 20102 12 12 SCRW PHD ST 10 32X3 8 PLTD T23 272Z 28 K9 141 152 6 SPARK MODULE MOUNT 272Z 29 2C 20102 04 12 SCRW PHD ST 8 32X 5 PLTD 272Z 30 2J 80300 17 6 SPRK IGN CNTRL 14...

Страница 28: ...7 6 5 4 3 2 1 SPARK MODULE SEC 1 SEC 2 POWER IN L1 N TEMPERATURE CONROLLER HEAT OUT SEC 3 SEC 4 SEC 5 SEC 6 SEC 7 SEC 8 1 2 3 4 5 6 7 8 VIEW FROM FRONT OF BOARD SPARK SENSE VALVE SECTION ONE SHOWN ALL...

Отзывы: