background image

 

Star Manufacturing International 

10 Sunnen Drive 

St. Louis, MO.63143-3800 

Part Number: 2M-W359 

Ph: 314-781-2777 Fax: 314-781-2714 

 

Rev. C 

WWW.STAR-MFG.COM

  

October 29, 2007 

2

 

Safety 

CAUTION:

 

THE GRIDDLE IS EXTREMELY HEAVY. FOR SAFE 
HANDLING, INSTALLER SHOULD OBTAIN HELP AS 
NEEDED, OR EMPLOY APPROPRIATE MATERIALS 
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, 
DOLLY, OR PALLET JACK) TO REMOVE THE UNIT 
FROM THE SKID AND MOVE IT TO THE PLACE OF 
INSTALLATION.

 

CAUTION:

 

ANY STAND, COUNTER OR OTHER DEVICE ON 
WHICH GRIDDLE WILL BE LOCATED MUST BE 
DESIGNED TO SUPPORT THE WEIGHT OF THE 
GRIDDLE. 

CAUTION:

 

SHIPPING STRAPS ARE UNDER TENSION AND CAN 
SNAP BACK WHEN CUT. 

DANGER:

 

THIS APPLIANCE MUST BE GROUNDED AT THE 
TERMINAL PROVIDED.  FAILURE TO GROUND THE 
APPLIANCE COULD RESULT IN ELECTROCUTION 
AND DEATH. 

WARNING:

 

INSTALLATION OF THE UNIT MUST BE DONE BY 
PERSONNEL QUALIFIED TO WORK WITH 
ELECTRICITY.  IMPROPER INSTALLATION CAN 
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE 
TO EQUIPMENT.  UNIT MUST BE INSTALLED IN 
ACCORDANCE WITH ALL APPLICABLE CODES. 

NOTICE: 

The data plate is on top of the control box. The 
griddle voltage, wattage, serial number, wire size, 
and clearance specifications are on the data plate.  
This information should be carefully read and 
understood before proceeding with the installation. 

NOTICE:

 

The installation of any components such as a vent 
hood, grease extractors, fire extinguisher systems, 
must conform to their applicable National, State and 
locally recognized installation standards. 

NOTICE:

 

During the first few hours of operation you may 
notice a small amount of smoke coming off the unit, 
and a faint odor from the smoke.  This is normal for a 
new griddle and will disappear after the first few 
hours of use. 

CAUTION:

 

ALWAYS KEEP THE AREA NEAR THE APPLIANCE 
FREE FROM COMBUSTIBLE MATERIALS. 

CAUTION:

 

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN 
AND DRY.  IF SPILLS OCCUR, CLEAN IMMEDIATELY, 
TO AVOID THE DANGER OF SLIPS OR FALLS. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

Содержание 224Z

Страница 1: ...al 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W359 Ph 314 781 2777 Fax 314 781 2714 Rev C WWW STAR MFG COM October 29 2007 Installation Operation and Maintenance Instructions Gas Griddle Mo...

Страница 2: ...RK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is on top of the...

Страница 3: ...SE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT THE USER SMELLS GAS THIS INF...

Страница 4: ...PAGE Safety 2 Table Of Contents 4 Equipment Description 7 Unpacking 9 Installation 10 Initial Start Up 13 Operation 14 Cleaning Procedures 19 Troubleshooting 20 Exploded View 22 Parts List 23 Wiring D...

Страница 5: ...components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards WARNING THIS APPLIANCE IS EQUI...

Страница 6: ...r in contact with stainless steel surfaces longer than 10 minutes Longer contact can cause corrosion NOTICE Service on this or any other Lang Manufacturing appliance must be performed by qualified per...

Страница 7: ...can be set between 400 F 200 C and 550 F 288 C in 5 increments The minimum temperature value can be set between 100 F and 175 F in 5 increments The controls reaction to changes in temperature is also...

Страница 8: ...PLIED 272Z 72 INCHES 162 000 162 000 ONE 3 4 NPT 115 VOLT 2 SUPPLIED SPECIFICATIONS AND INFORMATION GRILL SURFACE OVERALL CLEARANCE FROM NON COMBUSTIBLE SURFACES MODEL NUMBER WIDTH DEPTH SQUARE INCHES...

Страница 9: ...nded location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crating The griddle will arrive completel...

Страница 10: ...contact is made with the threaded nut at the top of the receiver tube Screw the leg counter clockwise until it is hand tight Tighten the setscrew on the receiver tube one per leg WARNING THIS APPLIANC...

Страница 11: ...to the manifold The pressure in the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with the appliance operating at full fire A 1 8 inch NPT...

Страница 12: ...ody 10 Insert the new spring from the conversion kit and install the adjustment screw over it 11 Place the regulator pressure range sticker over the existing pressure range sticker 12 Place caution st...

Страница 13: ...enter a lock out situation and the controller must be cycled off and then back on Once the burners ignite the griddle will automatically preheat the griddle to its default temperature of 125 F 52 This...

Страница 14: ...eter and or return to normal operation Starting the Griddle Press the Power button The control will conduct a self test then display Control ready At this time the ignition sequence will begin Each bu...

Страница 15: ...ow buttons for five seconds If a user access code as been set the display will prompt for the access code now If not it will prompt for an L or R arrow button this will scroll through one of ten Manag...

Страница 16: ...ER If EDIT is selected and no Day Parts currently exist the control asks if a new Day Parts is to be added Use the UP or DOWN to toggle between YES and NO then press ENTER If YES is selected the contr...

Страница 17: ...an unsafe condition may exist Alarm Description Test Slow Warm Up Griddle takes to long to get to operating temperature Verify Main Burner ignition Spark Gap Spark Module Wiring between Spark Module a...

Страница 18: ...e Left arrow Down arrow Enter Once code is confirmed press Enter to save Reset Factory Defaults This setting when activated will reset all settings back to the configuration that left the factory It m...

Страница 19: ...he griddle with a thin film of oil to prevent rusting Clean the exterior of the appliance with hot water and a mild detergent to maintain a gleaming appearance Re season the griddle plate after each c...

Страница 20: ...orrecting the problem contact the nearest Lang service representative or Star Manufacturing International Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the...

Страница 21: ...ections sparks but does not light Failed Probe Griddle Overloading Verify Main Burner ignition Verify Gas Pressure Verify Temperature Probe operation Review Griddle Loading Controller prompts Section...

Страница 22: ...iption 141 701 Wire Harness 1 GG Short harness plugs on the module works in lanes 3 and 4 141 701 Wire Harness 2 GG Middleharness plugs on the module works in lanes 2 and 5 141 703 Wire Harness 3 GG L...

Страница 23: ...1 MANIFOLD ASSY 2 224Z NAT ZC LP 22 K9 141 156 3 2 VALVE SHIELD 224Z NAT ZC LP 23 2V 80502 04 2 SOLENOID VALVE 120VAC 1 2PIPE 224Z NAT ZC LP 24 K9 141 156 1 2 VALVE MOUNT BASE 224Z NAT ZC LP 25 K9 141...

Страница 24: ...Z 18 K9 141 181 3 BAFFLE UNDER BURNER 236Z 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 236Z 21 K9 141 157 3 1 MANIFOLD ASSY 3 236Z 22 K9 141 156 3 3 VALVE SHIELD 236Z 23 2V 80502 04 3 SOLENOID VALVE 120VAC...

Страница 25: ...248Z NAT 248 NATSC 248Z LPSC 20 2V 80501 04 1 GAS REG 3 4X3 4 CLS I 248Z NAT 248 NATSC 2V 80501 05 1 GAS REG 3 4X3 4 CLS II 248Z LPSC 21 K9 141 157 4 1 MANIFOLD ASSY 4 248Z 22 K9 141 156 3 4 VALVE SHI...

Страница 26: ...2V 80501 04 1 GAS REG 3 4X3 4 CLS I 260Z 21 K9 141 157 5 1 MANIFOLD ASSY 5 260Z 22 K9 141 156 3 5 VALVE SHIELD 260Z 23 2V 80502 04 5 SOLENOID VALVE 120VAC 1 2PIPE 260Z 24 K9 141 156 1 5 VALVE MOUNT BA...

Страница 27: ...TBE UNON 3 8CC 1 2 272Z 27 2C 20102 12 12 SCRW PHD ST 10 32X3 8 PLTD T23 272Z 28 K9 141 152 6 SPARK MODULE MOUNT 272Z 29 2C 20102 04 12 SCRW PHD ST 8 32X 5 PLTD 272Z 30 2J 80300 17 6 SPRK IGN CNTRL 14...

Страница 28: ...7 6 5 4 3 2 1 SPARK MODULE SEC 1 SEC 2 POWER IN L1 N TEMPERATURE CONROLLER HEAT OUT SEC 3 SEC 4 SEC 5 SEC 6 SEC 7 SEC 8 1 2 3 4 5 6 7 8 VIEW FROM FRONT OF BOARD SPARK SENSE VALVE SECTION ONE SHOWN ALL...

Отзывы: