31
Matrix
Protection and Control Units
UW-MTX3.5/3.5EC/3.5H
UW-MTX4.5
* - Optional feature
Overload - Phase
Overload - Neutral
Short-Circuit
Directional Short-Circuit
Instantaneous
Earth-Fault
Current
Voltage
Frequency
Reverse Power
Maximum Demand
Last 20 trip data
Last 10 Event Data
Modbus
Profibus
Zigbee (wireless)
Trip Circuit Supervision (TCS)
Zone Selective Interlocking (ZSI)
Temperature Rise (TM)
Earth Leakage (EL)
Restricted Earth-Fault (REF)
Relay Output
Load Management (Pre Trip Alarm)
Digital Input & Output
Analog Output
Current
% Loading
Voltage
Power & Energy
Harmonics
Basic Protection
Additional
Protection
Trip Records
Event Records
Smart Card
Communication
Advanced Protection
Additional Features
Metering
Storable Settings (2 sets)
Auxiliary Supply (24V DC)
P
a
r
a
m
e
t
e
r
M
T
X
3
.
5 M
T
X
3
.
5
E
C
F
e
a
t
u
r
e
s
M
T
X
4
.
5
- Standard
P
P
P
P
P
P
P
P
P
P
P
P
P
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
-
-
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
*
*
*
*
*
*
*
*
*
*
*
*
P
P
P
P
P
P
P
P
P
P
P
P
P
P
*
P
P
P
P
P
*
*
*
*
*
*
*
*
*
*
*
*
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
*
*
*
*
*
*
*
*
*
*
*
P
U
W
-
M
T
X
3
.
5
H
M
T
X
3
.
5
H
UW-MTX4.5
?
?
?
UW-MTX3.5 H
Advance protection - ZSI, TCS,
Earth-fault protection with
REF & EL
variable current & time delay
Communication through
setting
Modbus, Profibus & wireless
Instantaneous protection
Zigbee
2
4
Smart Configurator module
I t, I t, SI, LI/VI protection
for easy parameterisation of
curves
the release
Directional & Double Short
Local & remote fault
circuit protections
annunciation & pre-trip alarm
Reverse power and phase
Current, Voltage, Power,
sequence protection
Energy & THD metering & %
2
Selectable I t based curves for
loading
short-circuit and earth-fault
Earth Fault Protection from
protection
10%In
Switchable neutral overload
protection (50%-200%) in
Dual time-based protection set
step of 5%
groups
Additional current & voltage
Thermal reflectivity & soft
based protections
rating-plug
Self-powered protection
Protection against
temperature rise
Trip & Event recording
Overload, Short-circuit and
UW-MTX3.5/3.5EC
Protection against
Earth-fault protection with
temperature rise
variable current & time delay
Advance protection - ZSI, TCS,
setting
REF & EL
Instantaneous protection
Optional communication
2
4
through Modbus, Profibus &
I t, I t, SI, LI/VI protection
wireless Zigbee
curves
Smart Configurator module
for easy parameterisation of
the release
Directional & Double Short
Local & remote fault
circuit protections
annunciation & pre-trip alarm
Reverse power and phase
Current, Voltage, Power,
sequence protection
Energy & THD metering & %
2
Selectable I t based curves for
loading
short-circuit and earth-fault
Dual time-based protection set
protection
groups
Switchable neutral overload
Thermal reflectivity & soft
protection (50%-200%) in
rating-plug
step of 5%
Self-powered protection
Additional current & voltage
Trip & Event recording
based protections
Overload, Short-circuit and
Current & Voltage
harmonics metering
UW-MTX3.5H
32
Matrix
Protection and Control Units
UW-MTX3.5H
UW-MTX3.5EC
?
?
Содержание OMEGA
Страница 2: ...Stabilise systems with technology ...
Страница 4: ...Change course quickly ...
Страница 6: ...Match performance with prudence ...
Страница 8: ...Adopt technological brilliance ...
Страница 10: ...Keep an eye on upkeep ...
Страница 26: ...Matrix Protection Control Units T UW M X4 5 ...
Страница 70: ...Accessories ...
Страница 84: ...Control Circuit Wiring ...
Страница 92: ...Mounting Termination ...
Страница 135: ...SP 50567 R5 ...