User friendly:
A
A11
A
A22
Shunt Release
220-240V~
PWR
O/L
S/C
IN T
S
EF
N R
T L
A RM
L
TRIP
F
O F
OFF
ON
E
Unique breaker front-facia architecture displays the electrical
accessories mounted on the ACB (with rated control voltage & type
of operating voltage)
E
redefine the modularity on a time scale of 5 mins.
Modular & snap-fit accessories such as UVR, SR & CR modules,
E
Draw-out version
Ease of on-site convertibility from Manual to Electrical & Fixed to
E
electrical contacts
Tool-less Arc-Chutes removal facilitates quick inspection of
E
Indelibly marked Breaker Specifications on facia with Laser Marking
E
RoHS complaint
21
ACB “
A Basket of Benefits
”
Switchboard friendly:
E
Three compact frame sizes help in optimizing the switchboard
E
switchboard
Right aligned design of ACB helps in better space utilization within the
E
100% neutral (as standard) help in designing the switchboards as per
applications & lead to optimized switchboard design
True 50% & 200% neutral options, along with the conventional
E
number of connection layouts & facilitate the easy modification of
panel design & busbar layouts
Common height & depth across the range help in reducing the
E
busbar arrangements
Terminal adaptors offer ease of configuration of vertical/horizontal
E
superior performance
Option of interleaving busbar design at breaker terminals offer
E
of arc-shield
Supports multi-tier arrangement with minimal clearance with the help
E
termination of 2 control wires (with Lugs) each of up to 2.5 sq.mm
Self-aligning, Snap-fit Secondary Isolating Contacts enable the quick
E
Option of customized neutral configuration ( For 100%N only)
E
mechanical interlocking among various frames of Fixed / Draw-out /
Mixed versions of Omega ACBs
2m/3m/5m Bowden wire mechanical interlocking kit facilitates ease of
E
clearance above
breaker facilitating Compact Multi-tier Switchboard design
Minimum 45mm* (Without Temperature Module)
E
Best in class (40mm) Termination overlap with Bus bars.
* Minimum 300mm in case of 800V/1000V AC ACBs
Содержание OMEGA
Страница 2: ...Stabilise systems with technology ...
Страница 4: ...Change course quickly ...
Страница 6: ...Match performance with prudence ...
Страница 8: ...Adopt technological brilliance ...
Страница 10: ...Keep an eye on upkeep ...
Страница 26: ...Matrix Protection Control Units T UW M X4 5 ...
Страница 70: ...Accessories ...
Страница 84: ...Control Circuit Wiring ...
Страница 92: ...Mounting Termination ...
Страница 135: ...SP 50567 R5 ...