![Landis+Gyr Gridstream IV Series Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/landis-gyr/gridstream-iv-series/gridstream-iv-series_user-and-installation-manual_673736061.webp)
Chapter 6 - Performing System Upgrades
Gyr
58
98-1031 Rev AA
Concentrator User and Installation Guide
Switchover Concentrator
After the download is complete, login to the concentrator to instruct it to switchover.
1.
Open a command window on your PC.
2.
Use your administrative credentials to login as control user.
3.
Type
./utlICDownload -mccad 30000.1 -session 2 -switchover
-disconnect
You need the disconnect session ID if the earlier download
was terminated before completion. In this case, you must
enter all the options of the download command and include
the disconnect session ID. That should be the same session
number that was terminated earlier.
Example: utlICDownload -disconnect 5
-nohotboot
Override automatic disconnect and hotboot to avoid hot
booting the MC be fore the session. In this case, you must
start run disconnect and hotboot.
Example: utlICDownload -nohotboot -session 5 -mccad
30000.1 -s <filename>
-waittime
Time to wait (in seconds) before sending the next packet. The
download firmware process sends a total of nine packets. The
waittime option allows for a delay between packets sent.
Example: utlICDownload -waittime 4
/MCCCTR/image.bin
[Args Reqd: 1 defaults: 2 format: %s]
-bankcopy
Copy Concentrator image from B to A. The Concentrator must
be running the image from B.
This option applies to versions 14.02.06 and greater.
Example: utlICDownload -mccad 30000.1 -bankcopy
-debugprint
Dump raw hex.
Example: utlICDownload -debugprint
[Args Reqd: 1 defaults: 2 format: %s]
-help
Print help information.
Example: utlICDownload -help
-query
Get status of concentrator.
Example: utlICDownload -query
-switchover
Switchover concentrator.
Example: utlICDownload -switchover
Table 6-1. Download Command Line Switches (continued)
Switch
Description
The concentrator hot boots after this step.