Data Sheet
AA00B.C13
landiaworld.com
Prepared by: BNV/GB
Approved by: KSK/TM
Issued on: 1 January 2018
Rev. date: 3 January 2019
ELECTRICAL DATA
Page 6/7
Motor type
3-phase AC motor
Nominal voltage
400 V
Minimum voltage allowed
360 V
Nominal frequency
50 Hz
Applicable for VFD operation
Yes
Ingress protection rating
IP 68
Insulation class
F
ATEX classification
Not possible
Model
It
em nu
mb
er
No
mi
nal
p
ow
er
Motor
Fu
ll lo
ad
curre
nt
(400 V)
Co
nne
ct
io
n
met
hod
Sta
rt c
ur
re
nt
(DOL)
cos
p
hi
Efficiency
[kW]
[rpm]
[A]
Y/
Δ
[A]
[%]
POPR-I 1.1/0.75 kW-150 rpm IE2
1136201
1.1
955
2.75
Y
15
0.71
78.1
POPR-I 4.0/3.0 kW-150 rpm IE2
1136204
4.0
965
8.5
Δ
43
0.79
85.5
POPR-I 7.5/4.0 kW-150 rpm IE2
1136207
7.5
970
15.5
Δ
91
0.79
87.5
POPR-I 3.0 kW-300 rpm
1114203
3.0
1,430
6.7
Δ
43
0.79
82.4
POPR-I 4.0 kW-300 rpm
1114204
4.0
1,435
8.8
Δ
61
0.78
84.1
POPR-I 7.5 kW-300 rpm
1114207
7.5
1,455
15.0
Δ
90
0.83
86.2
POPR-I 11.0 kW-300 rpm
1114211
11.0
1,455
21.5
Δ
146
0.84
87.9
POPR-I 15.0 kW-300 rpm
1114215
15.0
1,465
29.0
Δ
212
0.84
88.7
POPR-I 18.5 kW-300 rpm
1114218
18.5
1,460
35.0
Δ
238
0.85
89.3
POPR-I 22.0 KW-400 rpm
111422
3
22.0
1,465
43.0
Δ
280
0.82
90.1
POPR-I 30.0 kW-400 rpm
111423
1
30.0
1,465
57.0
Δ
399
0.84
90.7
For voltages others than 400 V/50 Hz please refer to the attached Appendix.