AC01A.C01
Service instruction POD-I
Page 2/5
Prepared by: AJ/CML
Issued on: 01 March1997
Approved by: SL
Rev. date: 12 March 2021
Introduction
POD-I is a horizontal submersible mixer.
The unit is placed in the cross section of the liquid to obtain the required mixing.
During operation, the mixer is locked by the guide pipe to obtain stability.
The mixing takes place by means of an electric motor; a propeller is installed on the motor shaft.
The oil filled oil chamber between motor and propeller provides cooling and lubrication of the mechanical seals.
The sealing system consists of two mechanical seals. The exterior seal separates the medium from the oil chamber;
the interior seal separates the oil from the motor casing.
The following pages describe the connection and the maintenance of mixers type POD-I.
Application
This mixer is to be used for flow creation, mixing and homogenization of liquids with a high or low dry matter content,
like e.g. wastewater, sludge and paper pulp, as well as chemical liquids and manure. The mixer can be placed in
square and circular tanks and is to be applied only fully submerged below liquid level.
If the mixer is to be applied for other purposes, contact Landia A/S for advice.
Warning
please note the following points:
•
Only a certified electrician is allowed to connect the unit.
•
Prior to installation and commissioning ensure that the equipment is installed correctly and fixed to the
mixer, as well as ensure that the equipment in the tank is fixed safely.
•
Prior to the first start of the mixer, the propeller shaft must be rotated manually. This also applies if the
mixer has not been in operation for a longer period.
•
The electrical cable is always to be tightened by means of the chain to prevent the cable from getting into
contact with the propeller. If the mixer is not supplied with a chain, the cable is to be protected against
damage in another way, e.g. by means of a cable mesh.
•
It must be ensured that the propeller cannot touch the tank.
•
It is always to be ensured that the mixer is fully below liquid level during operation.
•
Prior to hoisting the mixer at service/repair it is always to be ensured that the electrical connection of the
mixer is switched off or locked. Prior to service/repair the mixer should be cleaned thoroughly.
•
When the mixer is hoisted or lowered, its cable and chain are always to be placed outside the work area.
•
For service/repair of mixers installed in well/tank with explosion danger/toxic gases we refer to the national
safety directions as far as safety is concerned, e.g. concerning the toxic hydrogen sulphide.
Service/repair
To maintain a high operating safety and a long service life without unnecessary and expensive repair it is important
from the beginning to execute regular and preventive service. Maintenance should be executed according to the
intervals stated in the manual. The instructions should always be followed carefully and only apply the parts described
by Landia A/S in the spare parts list.
If you do not want to execute the service yourself - we can offer you a service agreement - please call for further
information.
Please note
If spare parts not identical to the recommended are applied at service/repair, the guarantee from Landia A/S will be
annulled. Spare parts can be ordered at Landia A/S or your local distributor.
For major repairs at a special workshop please contact:
Head Office:
UK subsidiary:
LANDIA A/S
Landia (UK) Ltd.
Industrivej 2
Waymills Industrial Estate,
DK-6940 Lem St.
Whitchurch,
Tel.: +45 97 341244
Shropshire SY13 1TT
Tel: + 44 01948 661 200
Содержание POP-1