9
A. Graduated Cylinder
B. Nozzle
A
B
Calibrating Brand Syrup Modules
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
4. Set the Timer to the ON position and select seconds (s) as
the desired unit of measurement.
5. Using the keypad, enter in a time of 4 seconds as the preset
dispensing time.
9. Repeat steps 6-8 until the designated volume of 30 ml is
achieved.
10. Repeat steps 2-9 for the remaining brand syrup modules.
11. Press the
Maintenance
button to return to the Maintenance
screen and then press the
Menu
button to return to the
Service menu.
1. From the Service menu, press the
Maintenance
button.
2. Press the
Calibrate
tab on the far left side of the screen and
press the
Calibrate
button for the first brand syrup module.
3. The water flow rate should be set from the calibration of
the plain water module in the previous section and the ratio
should be determined from when the brand was configured.
(See page 6,
Adding New Brand/Flavor Module
)
The refrigeration unit should have been running for at
least one (1) hour before attempting to set flow rates
on valves. The drink temperature should be no higher
than 40°F (4.4°C) when flow rates are set. This is best
done after the remote chiller has already made an ice
bank. (If applicable)
NOTE
The brand syrup modules can be calibrated the same
as the plain water module by using volume (ml). Below
are the steps to calibrate the modules using the unit of
time (seconds) instead of volume (ml).
NOTE
7. Examine the dispensed volume in the graduated cylinder.
8. If the dispensed volume does not match the value of 30.0
ml, (see table on next page) remove the protective cap for
the corresponding valve and use a screwdriver to adjust the
brand syrup flow control.
The finished drink flow rate was set to 60 ml/sec,
which makes the finished syrup flow rate 7.5 ml/s. In 4
seconds, the volume of syrup that should be
dispensed is 30 ml.
NOTE
6. With the graduated cylinder placed in a position below the
nozzle, press the
Start Purge
button. The unit will dispense
the designated syrup for 4 seconds.
A. Flow Rate/Ratio C. Start Purge Button
B. Timer Icon
D. Unit Icon
A
B
C
D