6
Once the purge is activated, it will continue to dispense
product until it is deactivated. To deactivate the purge,
simply press the
Purge
button again. Up to four
modules can be purged at one time. Once four
modules are selected, all other modules are grayed out
and cannot be selected.
NOTE
A. Regulator Adjustment Screw
B. Adjust to 65 PSI (0.448 MPa)
C. Wrench
A
B
C
Adding New Brand/Flavor Module
1. In order to add a new brand or flavor module, the module
must first be activated.
2. From the Service menu, press the
Valve Configuration
button.
3. Press the
Valve Type
tab on the far left side of the screen,
then select any of the inactive modules.
23. Purge the carbonated water module until gas-out.
24. Reactivate the pump deck at the remote chiller.
25. Purge the carbonated water module again until a steady flow
of carbonated water is achieved.
26. Purge each syrup module until a steady flow of syrup is
achieved.
A. Purge Tab
B. Up to 4 Purge Buttons Selected
C. ‘Grayed Out’ Purge Button
A
B
C
18. Press the
Purge
tab on the far left side of the screen.
19. Press the
Purge
buttons for both the plain water and the
carbonated water modules.
A. Valve Type Tab
B. Valve Type Button
A
B
20. Once a steady flow of water is achieved, press the
Purge
button again to deactivate the modules.
21. Ensure that the pump deck at the remote chiller is turned off
before turning on the CO
2
.
22. Turn on CO
2
at the source then, using a screwdriver, adjust
the high pressure regulator at the source to 65 PSI (0.448
MPa) then tighten locknut with wrench.
A
B
D
C
A. Discard Changes
C. Maintenance Button
B. Valve Configuration
D. Locale Change
17. From the service menu press the
Maintenance
button.