16
TROUBLE
CAUSE
REMEDY
BIB pump does not operate when
dispensing valve opened.
1. Out of CO
2
, CO
2
not turned on, or low CO
2
pressure.
2. Out of syrup.
3. BIB connector not tight.
4.
Kinks in syrup or gas lines.
5. Bad BIB Pumps.
1. Replace CO
2
supply, turn on CO
2
supply, or adjust CO
2
pressure to 70-80 Psi
(0.483-0.552 MPa)
2. Replace syrup supply.
3.
Fasten connector tightly.
4.
Straighten or replace lines.
5. Replace BIB pump.
BIB pump operated, but no flow.
1. Leak in syrup inlet or outlet line.
2. Defective BIB pump check valve.
1. Replace line.
2. Replace BIB pump
BIB pump continues to operate
when bag is empty.
1. Leak in suction line.
2.
Leaking o-ring on pump inlet fitting.
1. Replace line.
2. Replace o-ring.
BIB pump fails to restart after bag
replacement.
1. BIB connector not on tight.
2. BIB connector is stopped up.
3. Kinks in syrup line
4.
Bad BIB Pumps.
1. Tighten BIB connector.
2. Clean out or replace BIB connector.
3. Straighten or replace line.
4.
Replace BIB pump.
BIB pump fails to restart when
dispensing valve is closed.
1.
Leak in discharge line or fittings.
2. Empty BIB.
3. Air leak on inlet line or bag connector.
1. Repair or replace discharge
2. Replace BIB.
3. Repair or replace.
Low or no carbonation.
1. Low or no CO
2
.
2. Excessive water pressure.
3. Worn or defective carbonator pump.
4.
PCB malfunctioning.
1. Check CO
2
supply. Adjust CO
2
pressure to
70 Psi (0.483 MPa).
2. Water regulator should be set at 50 Psi
(0.345 MPa)
3. Replace carbonator pump.
4.
See page 19.
Post-Mix Troubleshooting
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was
purchased. Comply with local regulations regarding disposal of the refrigerant and
insulation.
Dispenser Disposal