background image

13

Monthly

•  Unplug the dispenser from the power source.
•  Remove the bonnet and clean the dirt from the gas cooler using a soft brush. 
•  Replace the bonnet and plug in the unit.

Every Six Months

•  Clean and sanitize the unit using the appropriate procedures outlined in the Cleaning and  

Sanitizing section of this manual.

Yearly

•  Clean water bath interior, including evaporator coils and refrigeration components.
•  Clean the entire exterior of the unit.

 

Following sanitization, rinse with end-use product until 

there is no aftertaste. Do not use a fresh water rinse. 

This is a NSF requirement. Residual sanitizing solution 

left in the system creates a health hazard.

CAUTION

Cleaning and Sanitizing Nozzles

A

B

C

A. Nozzle

B. Diffuser

C. Soda Lever

1.  Disconnect power, so as to not activate valve while cleaning.
2.  Remove nozzle by twisting counter clockwise and pulling 

down.

3. 

Remove diffuser by pulling down.

4.  Rinse nozzle and diffuser with warm water.

5. 

Wash nozzle and diffuser with cleaning solution then 

 

immerse in sanitizing solution and let sit for fifteen (15) 

minutes. 

6. 

Set nozzle and diffuser aside and let air dry. 

DO NOT

 rinse 

with water after sanitizing. 

7. 

Reconnect diffuser and nozzle.

8.  Connect power.
9. 

Taste the drink to verify that there is no off-taste. If off-taste 

is found, flush syrup system again.

Cleaning and Sanitizing Syrup Lines - BIB

1.  Disconnect syrup lines from BIB’s
2.  Place syrup lines, with BIB connectors, in a bucket of warm 

water.

3. 

Activate each valve to fill the lines with warm water and flush 

out syrup remaining in the lines.

4. 

Prepare Cleaning Solution described above. 

5.  Place syrup lines, with BIB connectors, into cleaning  

solution.

6. 

Activate each valve until lines are filled with cleaning solution 

then let stand for ten (10) minutes. 

7. 

Flush out cleaning solution from the syrup lines using clean, 

warm water.

 

Following sanitization, rinse with end-use product until 

there is no aftertaste. Do not use a fresh water rinse. 

This is a NSF requirement. Residual sanitizing solution 

left in the system creates a health hazard.

CAUTION

8.  Prepare Sanitizing Solution described above. 
9.  Place syrup lines into sanitizing solution and activate each 

valve to fill lines with sanitizer. Let sit for ten (10) minutes.

10. 

Reconnect syrup lines to BIB’s and draw drinks to flush 

 

solution from the dispenser.

11. 

Taste the drink to verify that there is no off-taste. If off-taste 

is found, flush syrup system again.

Содержание Delta-600 R-290

Страница 1: ...ved 9000 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Tech Support Warranty 800 729 1550 email custserv lancercorp com web lancercorp com Lancer PN 28 1002 01 01 Revision 0...

Страница 2: ...Assembly 21 Control Housing Assembly 22 Wiring Diagram 23 Plumbing Diagram 24 SAFETY NOTICES READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT This manual contains important safety information and...

Страница 3: ...lectrical connections If this dispenser is installed in an area that is susceptible to more than 10 variation of the nominal line voltage consider installing a surge protector or similar protection de...

Страница 4: ...9 kg ELECTRICAL 115 VAC 60 Hz 8 Amps 220 240 VAC 50 60 Hz 4 Amps PLAIN WATER SUPPLY Min Inlet Pressure 25 psi 0 172 MPa Max Static Pressure 65 psi 0 448 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 p...

Страница 5: ...p level Can the counter top support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting...

Страница 6: ...or damaged H WARNING Never energize the machine if there is any trace of damage Contact Lancer Customer Service for assistance H WARNING In order to facilitate proper dispenser drainage ensure that th...

Страница 7: ...the maximum performance of the dispenser the following MUST be adhered to CRITICAL to maximize performance 12 Remove yellow cap from the water bath fill hole and insert and insert a funnel into the fi...

Страница 8: ...connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING Do not use mechanical devices or ot...

Страница 9: ...cation to the 1 4 nut stem on the high pressure CO2 regulator attached to source and connect tubing DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING 5 Connect tubing routed from the syrup pump location...

Страница 10: ...he low pressure regulators on the regulator manifold to 75 Psi 0 517 MPa then tighten locknut with wrench 7 Activate each valve until gas out is achieved 8 Plug the Pump Motor Connector back into the...

Страница 11: ...diagnostic test properly disconnect it and try plugging it in again If the programmer still fails replace the programmer NOTE Handheld Programmer Volumetric Valve 1 Remove the ID panel from the front...

Страница 12: ...d Instruction warnings on the product being used must be followed Use sanitary gloves when cleaning the unit and observe all applicable safety precautions DO NOT use a water jet to clean or sanitize t...

Страница 13: ...ry DO NOT rinse with water after sanitizing 7 Reconnect diffuser and nozzle 8 Connect power 9 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again Cleani...

Страница 14: ...5 Bad syrup pump 1 Adjust CO2 pressure to 80 Psi 0 550 MPa minimum 70 Psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form upper body and clean...

Страница 15: ...h 3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 8 High beverage temperature 1 Correct prior to dispenser Consider...

Страница 16: ...BIB connector is stopped up 3 Kinks in syrup line 4 Bad BIB Pumps 1 Tighten BIB connector 2 Clean out or replace BIB connector 3 Straighten or replace line 4 Replace BIB pump BIB pump fails to restart...

Страница 17: ...spenser ON A green LED will be blinking every second upon startup 7 Observe time and check voltage of the PCB connections 8 Turn electrical power OFF for 15 seconds and then back ON again to reset Car...

Страница 18: ...Assembly 04 12 0097 Key switch Assembly 05 51 6711 Wrapper Assembly 06 30 13199 Drip Tray Bracket Right 07 30 13200 Drip Tray Bracket Left 08 42 0215 Foam Tank Assembly 09 05 3711 Drip Tray 10 05 1585...

Страница 19: ...ttom 04 30 5865 Fan Shroud Top 05 23 0985 Condenser 06 30 5867 Air Shield 07 52 3880 Fan Motor Assy 110V 240V 08 83 0082 Compressor Assembly 115V 83 0083 Compressor Assembly 230V 09 82 5215 Agitator A...

Страница 20: ...Assembly Syrup 1 3A 48 0474 Tubing Assembly Syrup 2 6V 3B 48 0475 Tubing Assembly Syrup 3 3C 48 0476 Tubing Assembly Syrup 4 3D 48 0477 Tubing Assembly Syrup 5 4 3 6 5 4V 3E 48 0478 Tubing Assembly S...

Страница 21: ...1 02 03 Carbonator Deck Pump Bracket Assemblies Item Part No Description 01 91 0063 Carbonator Motor 115V 91 0065 Carbonator Motor 230V 02 07 0017 Clamp with Screw 03 86 0084 Carb Pump 04 30 6800 Deck...

Страница 22: ...Screw 8 18 x 0 375 PHD w o Washer PH AB SH 09 12 0653 Filter Line IEC 250V 50 60 6A Panel MNT 10 06 3584 Wire Diagram Label 115 60 HZ 230 50 HZ 220 60 Hz Delta 06 R290 11 04 0072 Rivet 0 125 Dia X 0...

Страница 23: ...23 Wiring Diagram...

Страница 24: ...729 1550 custserv lancercorp com lancercorp com Plumbing Diagram PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S2 S1 S3 S4 S5 S6 PRESSURE SETTINGS CO 75 psi 50 psi WATER 2 PLAIN WA...