9
Installing CO
2
Supply / Dispenser Setup
DO NOT TURN ON CO
2
SUPPLY AT THIS TIME
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
!
WARNING
-
Thread regulator nut on to tank, then tighten nut with
wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
2.
Connect a 1/4” nut, stem and seal to CO
2
regulator outlet.
Then connect tubing routed from tee at syrup pumps.
3.
Using a wrench, loosen lock nut on regulator adjustment
screw then using a screwdriver back out lock nut screw all
the way.
A. CO
2
Regulator
B. 1/4” Nut, Stem & Seal
C. Line to Syrup Pumps
D. Oetiker Pliers
A
B
C
D
A. CO
2
Regulator
B. Screwdriver
C. Regulator Adjustment Screw
A
B
C
4. Turn on water source then purge water to fill carbonator
tank by opening carbonator relief valve. Close relief valve
once water begins to comes out of relief valve.
5.
Activate each valve until a steady flow of water is achieved.
6. Unplug the unit then unplug the Pump Motor Connector
from the control box. Use the wiring diagram either on the
unit control box or in the back of this manual for reference.
Failure to disconnect the motor power supply will
damage the carbonator motor, the pump and void the
warranty
F
ATTENTION
7. Turn on CO
2
and using a screwdriver, adjust regulator to 75
PSI (0.517 MPA) then tighten lock nut with wrench.
8. Activate each valve until gas-out is achieved.
9.
Plug the Pump Motor Connector back into the control box
then plug in unit.
Pump Motor will run for a few seconds to fill carb tank
NOTE
10.
Re-attach bonnet.
11.
Activate each valve until a steady flow of carbonated water
is achieved.