12
Cleaning and Sanitizing Solutions
Cleaning Solution
Mix a mild, non-abrasive detergent (e.g. Sodium Laureth
Sulfate, dish soap) with clean, potable water at a temperature
of 90°F to 110°F (32°C to 43°C). The mixture ratio is one
ounce of cleaner to two gallons of water. Prepare a minimum of
five gallons of cleaning solution. Do not use abrasive
cleaners or solvents because they can cause permanent
damage to the unit. Ensure rinsing is thorough, using clean,
potable water at a temperature of 90°F to 110°F. Extended
lengths of product lines may require additional cleaning solution.
Sanitizing Solution
Prepare sanitizing solutions in accordance with the
manufacturer’s written recommendations and safety guidelines.
The solution must provide 100 parts per million (PPM) chlorine
(e.g. Sodium Hypochlorite or bleach). A minimum of five
gallons of sanitizing solution should be prepared. Any sanitizing
solution may be used as long as it is prepared in accordance
with the manufacturer’s written recommendations and safety
guidelines, and provides 100 parts per million (PPM) chlorine.
Cleaning and Sanitizing Syrup Lines
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
1.
Disconnect syrup lines from BIB’s
2.
Place syrup lines, with BIB connectors, in a bucket of warm
water.
3.
Activate each valve to fill the lines with warm water and
flush out syrup remaining in the lines.
4.
Prepare Cleaning Solution described on previous page.
5.
Place syrup lines, with BIB connectors, into cleaning
solution.
6.
Activate each valve until lines are filled with cleaning
solution then let stand for ten (10) minutes.
7.
Flush out cleaning solution from the syrup lines using clean,
warm water.
8. Prepare Sanitizing Solution described above.
9.
Place syrup lines into sanitizing solution and activate each
valve to fill lines with sanitizer. Let sit for ten (10) minutes.
10.
Reconnect syrup lines to BIB’s and draw drinks to flush
solution from the dispenser.
11.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
Cleaning and Sanitizing Nozzles
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
1.
Disconnect power, so as to not activate valve while
cleaning.
2.
Remove nozzle by twisting counter clockwise and pulling
down.
3.
Remove diffuser by pulling down.
4. Rinse nozzle and diffuser with warm water.
5.
Wash nozzle and diffuser with cleaning solution then
immerse in sanitizing solution and let sit for fifteen (15)
minutes.
6.
Set nozzle and diffuser aside and let air dry.
DO NOT
rinse
with water after sanitizing.
7.
Reconnect diffuser and nozzle.
8.
Connect power.
9. Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
A
B
C
A. Nozzle
B. Diffuser
C. Soda Lever