Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the 

carrier accepts responsibility for the unit. Upon receiving the 

unit, carefully inspect the carton for visible damage. If 

damage exists, have the carrier note the damage on the freight 

bill and file a claim with carrier. Responsibility for damage to the 

dispenser lies with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS.......................3-4
 

Intended Use..............................................................3

 

Power Warning...........................................................3

 CO

2

 Warning...............................................................3

 

Water Notice...............................................................3

 

Agitation Warning........................................................4

SPECIFICATIONS AND FEATURES............................4-5
 

General System Overview..........................................5

PRE-INSTALLATION CHECKLIST...................................5
INSTALLATION...........................................................6-10
 

Unpacking the Dispenser............................................6

 

Selecting/Preparing a Counter Location.....................6

 

Dispenser Installation..............................................7-8

 

Installing Remote Syrup Pumps - BIB........................8

 

Connecting to Syrup Supply - BIB..............................9

 

Installing CO

2

 Supply / Dispenser Setup...............9-10

 

Adjust Water Flow Rate & Syrup/Water Ratio..........10

MAINTENANCE..............................................................11
 

Scheduled Maintenance...........................................12

CLEANING AND SANITIZING..................................11-12
 

General Information..................................................11

 

Cleaning and Sanitizing Solutions............................12

 

Cleaning and Sanitizing Syrup Lines........................12

 

Cleaning and Sanitizing Nozzles..............................12

TROUBLESHOOTING...............................................13-17
THE ELECTRONIC ICE BANK CONTROL (EIBC).......18
 

Checking the Normal PCB Operation.......................18

ILLUSTRATIONS AND PART LISTINGS..................20-29
 

Cabinet Assembly - High Performance...............20-21

 

Cabinet Assembly - 1500E and Pre-Mix..............22-23

 

Refrigeration Deck Assembly - USA...................24-25

 

Refrigeration Deck Assembly - Export.................26-27

 

Wiring Diagram - USA..............................................28

 

Control Housing Connections...................................28

 

Wiring Diagram - International..................................29

 

Plumbing Diagram - 5 Valve and 6 Valve.................29

SAFETY NOTICES

READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT.

This manual contains important safety information and all applicable safety precautions must be observed. To reduce 

the risk of fire, electric shock, damage to the equipment or personal injury when using this unit all instuctions/warnings 

on the product being used must be followed:

 

Text following the Warning signal indicates a            

hazardous situation, which if not avoided, will result 

in death or serious injury. Be sure to read all Warning 

statements before proceeding with the installation. 

WARNING

 

Text following the Caution signal indicates a             

hazardous situation, which if not avoided, could result 

in death or serious injury. Be sure to read the Caution 

statements before proceeding with the installation

CAUTION

 

Text following the Attention signal addresses a 

 

situation that if not followed could potentially damage 

the equipment. Be sure to read the Attention 

 

statements before proceeding

ATTENTION

 

Text following the Note signal provides you with 

 

information that may help you more effectively perform 

the installation procedures within this manual. 

 

Disregarding information will not cause damage or 

 

injury, however it may limit the performance of the 

 dispenser. 

NOTE

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product. 

Please carefully read the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user 

on the correct services and site location of the unit.

Содержание CED Series 1500

Страница 1: ...trademark of Lancer 2016 by Lancer all rights reserved 1500 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lan...

Страница 2: ...A 24 25 Refrigeration Deck Assembly Export 26 27 Wiring Diagram USA 28 Control Housing Connections 28 Wiring Diagram International 29 Plumbing Diagram 5 Valve and 6 Valve 29 SAFETY NOTICES READ ALL SA...

Страница 3: ...as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure that...

Страница 4: ...cm A Bonnet B Splash Plate C Cup Rest D Drip Tray A B C D This unit emits a sound pressure level below 70 dB DIMENSIONS Width 19 2 inches 487 mm Depth 24 inches 610 mm Height w out legs 25 4 inches 64...

Страница 5: ...Lancer PN 82 3401 or MC 163172 Water Regulator recommended CONSIDER THE FOLLOWING BEFORE INSTALLATION Location of Water Supply Lines Location of Drain Location of Electrical Outlet Location of Heating...

Страница 6: ...ing Preparing a Counter Location Failure to maintain specified clearance will cause the compressor to overheat and will result in compressor failure ATTENTION 6 15 1 The dispenser is designed to sit o...

Страница 7: ...illed water mixture 8 Flush water supply line thoroughly The water bath compartment must be filled with water before plugging in the unit otherwise the compressor fan may not operate properly ATTENTIO...

Страница 8: ...yrup pumps and install another tee fitting 5 Attach line from carbonator CO2 inlet to tee fitting between syrup pumps and CO2 supply A Tee Fitting B Line to Syrup Pump C Fitting D Line to CO2 Supply A...

Страница 9: ...egulator Adjustment Screw A B C 4 Turn on water source then purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water begins to comes out of relief valve 5 A...

Страница 10: ...water flow rate 5 oz in 4 sec Use a screwdriver to adjust if needed 4 Remove nozzle by twisting counter clockwise and pulling down then remove diffuser by pulling down 5 Install Lancer yellow syrup s...

Страница 11: ...NING AND SANITIZING Lancer equipment new or reconditioned is shipped from the factory cleaned and sanitized in accordance with NSF guidelines The operator of the equipment must provide continuous main...

Страница 12: ...water 3 Activate each valve to fill the lines with warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 5 Place syrup lines with BIB connectors...

Страница 13: ...flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 PSI 0 550 MPA minimum 70 PSI 0 480 MPA for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form upper bo...

Страница 14: ...3 Melt ice bank Remove all water Refill Locate possible syrup leak area and repair 4 Reposition water cage 5 Find leak and recharge unit If unit is not frozen 6 Turn water ON and shut unit OFF 7 Turn...

Страница 15: ...t water supply 3 Refrigeration system not running 4 Refrigerant leak 5 Condenser fan motor not working 6 Dirty condenser 7 Dispenser capacity exceeded 1 Check clearances around sides top and inlet of...

Страница 16: ...ow 90 of rated voltage 2 Refer to wiring diagram and correct 3 Replace starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure Compressor starts and runs...

Страница 17: ...lace syrup supply 3 Fasten connector tightly 4 Straighten or replace lines 5 Replace BIB pump BIB pump operated but no flow 1 Leak in syrup inlet or outlet line 2 Defective BIB pump check valve 1 Repl...

Страница 18: ...enser ON 8 Observe time and check continuity of the PCB screw lug connections 9 Turn electrical power OFF for 15 seconds and then back ON again to reset Carbonator timer Again measure continuity of th...

Страница 19: ...onment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrig...

Страница 20: ...20 Cabinet Assembly High Performance ILLUSTRATIONS AND PART LISTINGS 3 29 2 1 32 31 7 6 11 8 9 10 27 16 33 34 23 24 22 18 20 19 21 13 15 17 15 14 12 5 37 25 26 36 35 4 6 30 28 8...

Страница 21: ...onnector Housing 21 23 0389 Faucet Plate 6V 23 0394 Faucet Plate 5V 23 0771 Faucet Plate 4V 22 30 6644 Splash Plate without Logo 30 6644 01 Splash Plate with Logo 23 23 0159 Cup Rest 24 54 0017 Drip T...

Страница 22: ...22 Cabinet Assembly 1500E and Pre Mix 27 23 5 4 6 4 7 2 32 12 33 34 35 22 1 24 12 12 30 31 12 20 19 12 13 11 26 21 3 28 11 8 29 14 17 18 16 15 14 10 9 25 6...

Страница 23: ...Premix Valve 19 0258 Valve Premix Becker 18 30 6644 Splash Plate without Logo 30 6644 01 Splash Plate with Logo 19 23 0159 Cup Rest 20 54 0017 Drip Tray 21 12 0097 Key Lock Switch 22 52 0891 Harness A...

Страница 24: ...RTA NT WA TER BAT H FIL L HO LE BL BL W BL W BL TO JUNCTION BOX 39 37 T O 3 2 4 25 38 6 5 26 1 27 2 3 16 28F 19 TO 42 TO 18 18 TO 11 28G 17 43 23 9 44 15 30 41 29G 29 32 TO 4 TO 18 5 22 40 40A 40B 12...

Страница 25: ...otor Fan 115V 60Hz 9W 28D 30 5845 Bracket Fan Motor 28E 07 0354 Fan Blade 28F 06 0433 01 Label 115V 60Hz 9W 28G 04 0059 Screw 8 36 x 0 375 29 52 1259 Agitator Motor Assy 115V 60Hz 25W 29A 91 0084 Moto...

Страница 26: ...IMPOR TANT FILL WATER BATH UNTIL TANK OVERF LOW TUBE WATER FLOWS FROM TO TRANSFORMER LOAD TO COMPRESSOR TO TRANSFORMER LINE TO VALVES TO KEYLOCK 39 6 3 37 25 4 37 38 1 5 26 T O 3 2 2 TO 18 28A 28E 28B...

Страница 27: ...D 30 5845 Bracket Fan Motor 28E 07 0354 Fan Blade 28F 06 0670 Label 230V 50 60Hz 06 0433 01 Label 115V 60Hz 28G 04 0059 Screw 8 36 x 0 375 29 52 1259 Agitator Motor Assy 115V 60Hz 52 1379 Agitator Mot...

Страница 28: ...ITATOR MOTOR WHITE BLACK GREEN KILL SWITCH JCT COMPRESSOR LANCER ICE BANK CONTROL PROBE L RELAY S M M S FAN MOTOR C OVERLOAD WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DE...

Страница 29: ...3 TERM2 TERM1 B B W AGITATOR MOTOR COMPRESSOR DESCRIPTION CHASSIS GROUND CONTROL BOX CHAMFER PIN 1 PLAIN BLK RIBBED BLK 3 1 G G B W G B G ICE PROBE OPTIONAL MERCHANDISER FAN MOTOR LABEL WIRING DIAGRAM...

Страница 30: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: