Ice Bin Cleaning - Start-Up and Monthly

1.  Disconnect power to the dispenser
2.  Remove Top Cover.
3.  Melt out any remaining ice from the bin.
4.  Remove Agitator Pin from Agitator Shaft. Slide Agitator Shaft 

rearward out Hub and pull out of rear Bearing to remove.

5.  Remove Ice Shroud by lifting and rotating out from beneath 

the auger.

6.  Use the Cleaning Solution, and a clean cloth or soft brush, 

to clean all removable parts, sides of the Ice Bin, Auger, and 

surface of the aluminum casting.

7.  Using the Cleaning Solution and the sponge brush provided, 

clean all interior surfaces of the ice chute and the ice chute 

feed through.

8.  Repeat Step 6 for all exterior surfaces of the dispenser.
9.  Using hot water, thoroughly rinse away the cleaning solution.
10.  Wearing sanitary gloves, soak and clean cloth towel in   

Sanitizing  Solution  and  wash  all  surfaces  of  removable                     

parts, sides of the Ice Bin, Auger, and surface of the         

aluminum casting.

11.  Using the Sanitizing Solution and the sponge brush            

provided, clean all interior surfaces of the ice chute and the 

ice chute feed through.

12.  Repeat Step 10 for all exterior surfaces of the dispenser.
13.  Wearing sanitary gloves, reassemble all removable parts. 

Ensure agitator clip is locked.

14.  Fill Unit with ice and replace Top Cover.
15.  Reconnect Dispenser to power source.

 

Refer to the Automatic Agitation Warning on page 3.

NOTE

Cleaning and Sanitizing Syrup Lines - Bag in Box

1.  Disconnect syrup lines from BIB’s
2.  Place syrup lines, with BIB connectors, in a bucket of warm 

water.

3.  Activate each valve to fill the lines with warm water and flush 

out syrup remaining in the lines.

4.  Prepare Cleaning Solution described above. 
5.  Place syrup lines, with BIB connectors, into cleaning        

solution.

6.  Activate each valve until lines are filled with cleaning        

solution then let stand for ten (10) minutes. 

7.  Flush out cleaning solution from the syrup lines using clean, 

warm water.

8.  Prepare Sanitizing Solution described on previous page. 
9.  Place syrup lines into sanitizing solution and activate each 

valve to fill lines with sanitizer. Let sit for ten (10) minutes.

10.  Reconnect syrup lines to BIB’s and draw drinks to flush  

solution from the dispenser.

Cleaning and Sanitizing Syrup Lines - Figal Tank

1.  Disconnect syrup inlet from the figal syrup tank.
2.  Prepare cleaning solution and using a plastic bristle brush, 

scrub both disconnect valves on figal tank with cleaning  

solution and rinse with clean, potable water.

3.  Prepare sanitizing solution and using a spray bottle or clean 

cloth, sanitize both disconnect valves on figal tank and allow 

to air dry. 

4.  Turn off CO

2

 supply.

5.  Connect syrup line to syrup tank filled with clean, potable 

water. 

6.  Connect CO

2

 line to tank filled with water and pressurize.

7.  Activate appropriate valve to fill the line with water and flush 

out syrup remaining in the line.

8.  Disconnect CO

2

 line and syrup line from tank filled with 

water.

9.  Fill a seperate tank with cleaning solution and connect syrup 

line and CO

2

 line to tank and pressurize. 

10.  Activate appropriate valve to fill the line with cleaning       

solution then let stand for ten (10) minutes.

11.  Disconnect CO

2

 line and syrup line from tank filled with 

cleaning solution then reattach lines to tank filled with water 

and pressurize.

12.  Activate valve to flush cleaning solution from the line.
13.  Disconnect CO

2

 line and syrup line from tank filled with water 

then fill a seperate tank with sanitizing solution.

14.  Connect both CO

2

 and syrup lines to tank filled with          

sanitizing solution and pressurize.

15.  Activate valve to fill line with sanitizing solution then let stand 

for ten (10) minutes.

16.  Disconnect lines from the sanitizer tank and reattach to    

syrup tank and pressurize. 

17.  Draw drinks and refill line with end use product to flush    

sanitizing solution from the line. 

18.  Taste the drink to verify that there is no off-taste. If off-taste 

is found, flush syrup system again. 

19.  Repeat procedure for each valve/syrup tank. 

 

Following sanitization, rinse with end-use product  

 

until there is no aftertaste. Do not use a fresh water    

 

rinse. This is a NSF requirement. Residual sanitizing    

 

solution left in the system creates a health hazard.

CAUTION

 

Following sanitization, rinse with end-use product  

 

until there is no aftertaste. Do not use a fresh water    

 

rinse. This is a NSF requirement. Residual sanitizing    

 

solution left in the system creates a health hazard.

CAUTION

11.  Taste the drink to verify that there is no off-taste. If off-taste 

is found, flush syrup system again.

Содержание Bevariety ACIB Series

Страница 1: ...s not a toy Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons inclu...

Страница 2: ...local standards It is the responsibility of the installer to ensure compliance Water Notice Units are equipped with an automatic agitation system and will activate unexpectedly Do not place hands or f...

Страница 3: ...chilled products 30 only or two chilled and one ambient product on each MVU pad Capable of dispensing flavor shots Replaces the two center LEVs Provides additional carb or non carb beverage flexibili...

Страница 4: ...ack and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the remaining three sides Level unit if necessa...

Страница 5: ...the left side wall Dispenser Installation The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with...

Страница 6: ...ocation to the tee fitting at water line 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection installed in the previous...

Страница 7: ...aking connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING A Regulator Adjustment Screw B...

Страница 8: ...ctivate valve to purge syrup until steady flow is achieved 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver...

Страница 9: ...press the Push button one time to change to a non carb beverage 3 Press the same brand button again to change to a carbonat ed beverage light will flash slowly 4 Press the button one more time to chan...

Страница 10: ...n to capture a sample Self Serve Crew Serve 8 Verify that the syrup level is even with the water level Use screwdriver to adjust appropriate LFCV if necessary 9 Repeat steps 7 8 for each brand on MVU...

Страница 11: ...save 60 seconds after all changes have been made NOTE 5 Repeat Steps 2 4 for each of the desired brands 6 Press the Pour Cancel button to save Cleaning Solution Mix a mild non abrasive detergent e g...

Страница 12: ...lush solution from the dispenser Cleaning and Sanitizing Syrup Lines Figal Tank 1 Disconnect syrup inlet from the figal syrup tank 2 Prepare cleaning solution and using a plastic bristle brush scrub b...

Страница 13: ...off power to the dispenser 2 Remove Merchandiser 3 Remove Ice Chute Lever then remove Splash Plate Assembly by lifting it up and out from the dispenser face 4 Remove the Ice Chute Assembly base by rem...

Страница 14: ...14 WIRING DIAGRAMS ACIB 22 30...

Страница 15: ...15 PLUMBING DIAGRAMS ACIB 22 30...

Страница 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...