Installing CO
2
Supply
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
2. Connect a 1/4” nut, stem and seal to CO
2
regulator outlet.
3. Route appropriate tubing from the low pressure CO
2
regulator manifold location to the 1/4” nut, stem on the high
pressure CO
2
regulator attached to source and connect
tubing.
A dedicated CO
2
regulator is required to supply the CO
2
inlet at the unit as well as to all syrup pumps.
!
ATTENTION
4. Connect tubing routed from the CO
2
inlet at the unit to one of
the low pressure CO
2
regulator manifold outlets.
5. Connect tubing routed from the tee at the syrup pumps to
the second outlet of the low pressure CO
2
regulator manifold.
A
B
C
D
A. Line to Dispenser
B. Line to Syrup Pumps
C. Line to CO
2
Regulator
D. CO
2
Regulator Manifold
Remote Pump Installation
1. If necessary, install water booster (Lancer PN MC-163172)
between water supply and the unit.
2. Using tubing cutters, cut water line and install tee fitting, then
route appropriate tubing from the remote pump location to
the tee fitting at water line.
3. Connect line from tee fitting at water line to the remote pump
deck inlet regulator.
4. Complete the carbonated water line connection, installed in
the previous section, between the remote pump deck and
carbonated water inlet on the unit.
5. Install a shut-off valve in the water line feeding the deck. If a
separate water line is run for plain water, ensure that it also
has a shut-off valve.
A
A. Drain Fitting
B. Drain Line
C. Drip Tray
B
C
Pouring hot water down the drain may cause the Drain
Tube to collapse. Allow only luke warm or cold water to
enter the Drain Tube.
Pouring coffee, tea, or other
similar substances down the drain may cause the Drain
Tube to become clogged.
!
ATTENTION
A
B
C
D
A. Tee Fitting
B. Line to Plain Water Inlet
C. Line to Water Source
D. Line to Remote Pump
A
B
C
A. Oetiker Pliers C. Pump Inlet
B. Line to Tee Fitting D. Pump Outlet
D
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
-
Thread regulator nut on to tank, then
tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
A. CO
2
Regulator
B. 1/4” Nut, Stem & Seal
C. Line to CO
2
Regulator
Manifold
D. Oetiker Pliers
A
B
C
D