17
4
Technical Data
Temperature - humidity - coupling
0 ... 95 % not condensing
Wear and tear parts
none
Application in hazardous areas
F200K .... Ex-II
Device group/category of
hazardous area, certificate
[Ex] II 3G, Zone 2,
[Ex] II 3D, Zone 22
IECEx IBE 15.0012X
Class I Division 2
File-No. E488138
Marking
Ex nA nC IIC T6...T5 Gc X
Ex tc IIIC T85°C Dc X
Cl I Div2 Gr A T5
Standards
IEC 60079-0, EN 60079-0
ANSI/ISA-12.12.01,
CAN/CSA C22.2 No. 213
Operating temperature range
Ambient temperature
T5 -40°C/-40 °F ... Ta ... +75°C/+167 °F
T6 -40°C/-40 °F ... Ta ... +65°C/+149 °F
Additional Information
Follow the section "Special Points to
Note When Using the Device in Explosion-
proof Areas".
Application in hazardous areas
F200K .... Ex
Device group/category of
hazardous area, certificate
[Ex] II 2G, Zone 1
[Ex] II 2D, Zone 21
Certificate
IECEx EPS 14.0042X,
EPS 14 ATEX 1 696 X
Marking
Ex db IIC T6...T5 Gb
Ex tb IIIC T80°C, T95°C Db
Standards
IEC 60079-0 , EN 60079-0
Operating Temperature range
T5 -40 °C/-40 °F ... Ta ... +75 °C/+157 °F
(UV Version)
T6 -40 °C/-40 °F ... Ta ... +65 °C/+149 °F
(UV Version)
Ambient temperature
T6-40 °C/-40 °F ... Ta ... +60 °C/+140 °F
(IR Version)
Additional information
Follow the section "Special Points to note
when using the device in explosion-proof
areas".
Содержание F200K Series
Страница 1: ...www lamtec de Sensors and Systems for Combustion Engineering Manual F200K Compact Flame Scanner ...
Страница 2: ......
Страница 39: ...38 7 Instructions on Commissioning and Maintenance ...
Страница 71: ...70 11 Commissioning Protocol 11 Commissioning Protocol ...
Страница 72: ...71 12 EU Declaration of Conformity 12 EU Declaration of Conformity ...
Страница 73: ...72 12 EU Declaration of Conformity ...