![Lambrecht rain[e]observer Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/lambrecht/rain-e-observer/rain-e-observer_operating-instructions-manual_3392897031.webp)
Operating Instructions
rain[e]observer
Operating Instructions
rain[e]observer Precipitation Measuring System
11.8 Descriptive sensor parameter register (holding register)
Register
Parameter name
Number of
registers
Note
Access type
40050
Device identification number
(15 characters)
8 (2 characters
in each register)
The returned data have the
form of a 16 byte string with
zero termination.
Read only
40100
Serial number
(11 characters)
6 (2 characters
in each register)
The returned data have the
form of a 12 byte string with
zero termination.
Read only
40150
Firmware version
(up to 25 characters)
13 (2 characters
in each register)
The returned data have the
form of a 26 byte string with
zero termination.
Read only
Example:
Calling up the device identification number
(The identification number shown in the example is sensor-dependent. It is used here only for demonstration
purposes).
ASCII
05 03 9C 72 00 08 CB C3 05 03 10
30 30 2E 31 36
00.16480.000130.
34 38 30 2E 30 30 30 31 33 30 00
37 CA
LEN
6
Transmission
Query =>
Source
Master
Dest
Slave 5
Function
Read Holding Register (3)
Func Desk
Address=40050, Quantity of Register=8
Checksum
OK:C3CB
LEN
19
Transmission
Response <=
Source
Slave 5
Dest
Master
Function
Read Holding Register (3)
Func Desk
Byte count=16
Data
30 30 2E 31 36 34 38 30 2E 30 30 30 31 33 30 00
Checksum
OK:CA37
11.9 Sensor parameters / configuration parameters
Register
Parameter name
Allowed values
Number of
registers
Access type
40001 Modbus address device
1
Write only
40200 Baud rate
96 = 9600
192 = 19200
384 = 38400
1
Write only
40201 Parity
1 = even
0 = none
1
Write only
The device must be restarted after any setting is changed.
Example
Changing the RTU address from 3 to 1
03 10 9C 41 00 01 02
00 01
2D E8 03 10 9C 41 00 01 7E 6F
LEN
9
Transmission
Query =>
Source
Master
Dest
Slave 3
Function
Write Multiple Register (16)
Func Desk
Address=40001, Quantity=1
Byte count
2
Register values
00 01
Checksum
OK:E82D
LEN
6
Transmission
Response <=
Source
Slave 3
Dest
Master
Function
Write Multiple Register (16)
Func Desk
Address=40001, Quantity=1
Checksum
OK:6F7E
31