Operating Instructions
rain[e]observer
Operating Instructions
rain[e]observer Precipitation Measuring System
Implemented SDI-12 commands:
Command
Function
Sensor response
a!
Activity confirmation
a<CR><LF>
?!
Address query command
a<CR><LF>
a
I
!
Send identification
allccccccccmmmmmmvvvxx...xx<CR><LF>
aAb!
Change address
b<CR><LF>
aM!
Start measurement
atttn<CR><LF>
aMC!
Start measurement with CRC
atttn<CR><LF>
aC!
Start parallel measurements
atttnn<CR><LF>
aCC!
Start parallel measurements with CRC
atttnn<CR><LF>
aD0!
aD1!
Send data (buffer 0)
Send data (buffer 1)
If required with CRC
a<Werte<CR><LF>
a<Werte><CRC><CR><LF>
aM1!
Generate variance
atttn<CR><LF>
aM2!
Generate heating data
atttn<CR><LF>
aM3!
Start measurement intensity (mean value, maxi
-
mum and minimum)
atttn<CR><LF>
aMC1!
Generate variance with CRC
atttn<CR><LF>
aMC2!
Generate heating data with CRC
atttn<CR><LF>
aMC3!
Start measurement intensity (mean value, maxi
-
mum and minimum) with CRC
atttn<CR><LF>
aC1!
Generate variance
atttnn<CR><LF>
aC2!
Generate heating data
atttnn<CR><LF>
aC3!
Start measurement intensity (mean value, maxi
-
mum, minimum)
atttnn<CR><LF>
aCC1!
Generate variance with CRC
atttnn<CR><LF>
aCC2!
Generate heating data with CRC
atttnn<CR><LF>
aCC3!
Start measurement intensity (mean value, maxi
-
mum, minimum) with CRC
atttnn<CR><LF>
aV!
Start verification
atttn<CR><LF>
a = Address of the corresponding sensor; standard sensor address = 0
SDI-12 commands always begin with the address of the corresponding sensor. All the other sensors on the same
bus therefore ignore such commands. SDI-12 commands end with a
!
. All sensor responses also begin with the
address of the sensor, but end with the ASCII characters for carriage return,
<CR>
and line feed,
<LF>
.
The SDI-12 protocol is based on the ASCII character set. The baud rate is 1,200 Bd and has the byte frame
format:
1 Start bit
7 Data bits (least significant bit first)
1 Parity bit (even parity))
1 Stop bit
Activity conformation - a!
This command ensures the sensor is responding to inquiries. Essentially, it asks the sensor to confirm that it is
connected to the bus.
The sensor responds with its address and the characters
<CR><LF>
.