- 1
-
INSTALLATION
ENGLISH
Adjusting the minimum pressure
The gas pressure at the burner must be checked through the
pressure outlet positioned on the gas valve outlet pipe using a
water pressure gauge or a micro pressure gauge
- Remove the protection cover (G).
- Disconnect the power cable (12V) from the modulating coil.
- Adjust the minimum pressure to the value indicated in the table
below, screwing down (to increase) or unscrewing (to decrease)
the adjusting screw (I).
- Reconnect the power cable (12V) of the modulating coil.
- Seal the regulator with a cover (G).
As proof of conversion apply the adhesive label provided in the conversion kit above the technical data plate
bearing the information on the gas for which the boiler was set up at the factory.