INSTALLATION
ENGLISH
INSTALLATION
The boiler must be installed by qualified persons.
The installation must be in conformity with the provisions of the law regarding evacuation of the combustion products in
accordance with the REGULATIONS IN FORCE.
The combustible gases must be evacuated through a pipe with a diameter not less than that on the boiler and it must be
connected to a flue suited to the system capacity.
The following rules apply for dimensioning between the boilers and the flues:
- They must be easy to dismantle.
- They must be hermetically sealed and made of a material suitable to resist the combustion products and their possible
condensation.
- They must not have any regulating devices (valves). If these devices have already been fitted, they must be removed.
- They must not protrude from the flue but stop before its internal face.
PLACE OF INSTALLATION
The boiler has been designed for installation in homes.
The place of installation must be free of dust, flammable objects
or materials or corrosive gases. The room must be dry and not
subject to frost.
If the boiler is enclosed in or fitted on the side of cabinets, leave
enough space to be able to carry out the normal maintenance
activities. The figure shows the minimum space to be left around
the boiler.
GAS CONNECTION
Make the gas connection in accordance with the regulations in force.
The boiler must be connected with an approved rigid metal pipe or a flexible stainless steel pipe with continuous wall.
Corrugated metal pipes must be installed so that they do not exceed a length of 2000 mm at maximum extension. The
boilers are calibrated and tested to operate with NATURAL GAS and LIQUID GAS category II 2H3+ at a nominal pressure
of 20 mbar, 28/30 mbar and 37 mbar, respectively.
SYSTEM STARTUP
- Bleed the air from the system.
- Check that there are no gas leaks (use a soapy solution or similar product).
CHARACTERISTICS OF THE BOILER WATER
If the water is hard and aggressive, LAMBORGHINI recommends installation of
a proportional polyphosphate feeder (DOP/B) to prevent possible scaling in the boiler.
Water treatment is essential in the following cases:
- Widely extended systems (with large amounts of water).
- Frequent infeed of make-up water into the system.
- Sanitary water circuits.
Should the system need to be drained partially or completely, subsequently fill it with treated