INSTALLATION
HYDRAULIC CONNECTION
After securing the support hooks, position the template so that it sits flush with the wall. Starting from the end unions
previously fitted on the template, proceed with installation of all the pipes: system delivery, system return, cold water, hot
water, and possibly also gas and electric line with ambient thermostat.
Having fitted the pipes, screw on the end unions and fit normal closed caps to continue with the hydraulic system test. The
template can be removed or left on the wall, since after the wall finishing operations (plastering or tiles) it will be completely
sunk into the wall. Only the two support hooks will remain outside the finished wall as well as an opening in correspondence
to the couplings. Position the boiler on the two support hooks up against the finished wall using the holes on the rear of
the boiler body and fasten the two check nuts on the hooks. Then continue with the hydraulic connection using the pipes
provided, cutting them to size according to the distance between the unions on the boiler and the unions on the template
on the wall.
C
Electrical power supply
G
Gas
Ø 3/4” (in the boiler)
Ø 1/2” (in G./connections)
F
Boiler feed water
Ø 1/2” (cold)
AE
Electrical power supply
M
System delivery pipe
Ø 3/4”
R
System return pipe
Ø 3/4”
GS
Support hooks
Ø 10 mm.
FX
Extra fastening holes
Ø 11 mm.
N.B.
Use female hydraulic couplings.
TIPS AND SUGGESTIONS TO PREVENT VIBRATION
AND NOISE IN THE SYSTEMS
- Avoid using pipes with small diameters.
- Avoid using small-radius elbows and large cross-
section reducers.
-
It is recommended to hot wash the system
in
order to eliminate the impurities coming from the
pipes and radiators (in particular oils and greases)
which
may damage the circulator
.