51
-
Set the access code (62) (see page 48)
-
Press MODE
-
Press STEP to display the relative PHASE (F-G)
-
Use the +/- keys to set the desired r.p.m.
-
Press STORE to enter the variation.
VARYING FAN R.P.M.
GAS VALVE ADJUSTMENT
The boilers leave the factory already set to their minimum and maximum output and therefore do not
need to be set when installed.
Should the settings need to be modified to adapt them to installation requirements it will be necessary
to change fan r.p.m. and reset the CO
2
value to between 8.8-9%.
Legend
A Minimum
heat deliver y
adjustment screw
B
Maximum
heat deliver y
adjustment screw.
In the event of gas valve replacement, proceed as follows:
1
Insert a combustion analysis instrument.
2
Position the switch to SUMMER or WINTER and open
a tap on the hot water circuit.
3
Wait a few seconds for the boiler to reach max.
power (check the fan r.p.m. on the display).
4
Adjust the gas flow-rate by acting on screw B until
the CO
2
value is between 8.8 and 9%.
5
Keep the hot water tap open, select PHASE E and set
parameter “1” to automatically set the boiler to
minimum power.
6
Adjust the gas flow-rate by acting on screw A until
the CO
2
value is between 8.8 and 9%.
7
Repeat steps 4-5-6- until combustion values stabilise
when passing from minimum to maximum power and
vice versa.
When adjustment is over bring PHASE E back from 1 to
0. This parameter variation restores boiler modulation.
54
Enhorabuena...
... por la óptima elección.
Le agradecemos la preferencia dada a nuestros productos.
LAMBORGHINI CALORECLIMA está presente activamente desde 1959 en Italia y en el mundo
con una red ramificada de Agentes y Concesionarios, que garantizan constantemente la
presencia del producto en el mercado. A todo ello se une un servicio de asistencia técnica,
“LAMBORGHINI SERVICE”, cualificado en el mantenimiento del producto.
Para la instalación y para la colocación de la caldera:
RESPETEN ESCRUPULOSAMENTE LAS NORMAS LOCALES VIGENTES.
ÍNDICE
PÁGINA
NORMAS GENERALES ____________________________ 55
DESCRIPCIÓN ___________________________________ 56
INSTALACIÓN ___________________________________ 57
COMPONENTES PRINCIPALES _____________________ 58
MEDIDAS _______________________________________ 59
CARACTERÍSTICAS TÉCNICAS _____________________ 59
CONEXIÓN HIDRÁULICA _________________________ 60
CIRCUITO HIDRÁULICO ___________________________ 61
CONEXIONES ELÉCTRICAS - ESQUEMAS ____________ 62
INSTALACIÓN CONDUCTO EXPULSIÓN DE HUMOS __ 65
FUNCIONAMIENTO ______________________________ 66
ENCENDIDO ____________________________________ 67
TABLERO DE MANDO ____________________________ 67
REGULACIÓN DE LA TEMPERATURA DE CALEFACCIÓN ____ 67
SECUENCIAS DE FUNCIONAMIENTO ______________ 68
LISTA DE LAS FASES INDICADAS POR LA PRIMERA CIFRA DE LA PANTALLA ____ 69
VISUALIZACIÓN DE LOS DATOS (sistema MONITOR) __ 70
CÓDIGO DE BLOQUEO ___________________________ 71
DESBLOQUEO DEL APARATO ______________________ 72
VISUALIZACIÓN Y MODIFICACIÓN DE LOS PARÁMETROS (CÓDIGO DE ACCESO) _ 72
REGULACIÓN DE LA VÁLVULA DEL GAS ____________ 75
VARIACIÓN DEL NÚMERO DE REVOLUCIONES DEL VENTILADOR __ 75
REGULACIÓN GAS - BOQUILLAS __________________ 76
CURVA DE PRESIÓN EN EL QUEMADOR - POTENCIA SUMINISTRADA ___ 76