36
WATER SUPPLY CONNECTION
Fit the assembly template up against the wall. Then fit all the piping: system delivery, system return,
cold water, hot water, gas, condensation discharge and electrical power supply for the room thermostat.
Once the pipes have been fitted the end fittings can be unscrewed and ordinary plugs can be inserted
ready for water supply tests to be carried out.
CONDENSATION DISCHARGE
The condensation which forms inside the boiler must be discharged. The boiler is fitted with a condensation
trap. The trap fitting must be connected to a Ø 32 mm PVC outlet pipe. It is advisable to instal a second
trap upstream from the plumbing system.
LEGEND
C
Hot water Ø 1/2”
G
Gas Ø 3/4”
F
Boiler water supply Ø 1/2” (cold)
AE
Electrical supply
M
System delivery Ø 3/4”
R
System return Ø 3/4”
SC
Condensation discharge Ø 80 mm
NOTE: Preview hydraulic female connections.
Maximum external dimensions
of discharge: Ø 70 mm max.
and H 25 mm max.
Comfort water supply connection kit (available on
request)
Important: When replacing the
condensation discharge pipe,
supplied with the boiler, use a
pipe with an internal diameter of
13 mm.
69
Para acceder al número de la FASE hay que presionar una vez el botón MODE (aparece un punto
luminoso fijo a la derecha de la 1
a
cifra). Presionar el botón STEP para visualizar todas las FASES
disponibles.
LISTA DE LAS FASES INDICADAS POR LA PRIMERA CIFRA DE LA PANTALLA (Valores que puede modificar el usuario)
Ejemplo:
punto luminoso fijo
pantalla
n
°
fase
pantalla valor
parámetros
2
N
°
fase
Parámetro
Campo de valores
00 = agua caliente sanitaria
desconectada
01 = 5
°
C histéresis + bomba con-
tinuamente en el circ. sanita-
rio
02 = 5
°
C de histéresis
03 = 10
°
C de histéresis
04 = 20
°
C de histéresis
05 = 30
°
C de histéresis
1
Temperatura agua sanitaria
de 60 a 90
°
C
02
Sistema agua caliente sanitaria
00 = calefacción desactivada
01 = calefacción activada
02 = calefacción activada y
bomba que funciona con-
tinuamente
01
3
Calefacción
4
80
Temperatura de ida
de 20 a 90
°
C
80
Valores programados
(default)
Para abandonar el programa LISTA DE FASES hay que presionar dos veces