35
DIMENSIONS mm
3/4” Ø heating delivery
3/4” Ø heating return
1/2” Ø cold water inlet
1/2” Ø hot water outlet
3/4” Ø gas inlet
TECHNICAL FEATURES
Boiler version: mod. C type C13-C33-C43-C53-C83
Max. water temperature 90
°
C
Category: I 2H
Rated gas pressure: Natural gas 20 mbars
Heating circuit operating pressure max. 3 bars
Hot water circuit operating pressure max. 6 bars
MODEL
Thermal capacity
Min. thermal capacity
Hot water supply
Weight
Input
Output
50/30ºC
kW kcal/h kW kcal/h
min.
l
l kg
25 21.500 25,75 22.145
680 145
3 89
FUTURIA 24
PLUS MB W TOP
Output
80/60ºC
kW kcal/h
24,5 21.070
Input
Output
50/30ºC
kW kcal/h kW kcal/h
8,8 7.568 9,33 8.022
Output
80/60ºC
kW kcal/h
8,98 7.719
Water
supply
∆
30ºC
Peak flow
over first
10 min.
Reset
Water-
heater
capacity
l/h
l
10
90
Expansion
tanks
l
8
Hot
water
Heating
CIRCULATING PUMP FEATURES
Delivery/pressure available at the system
70
VISUALIZACIÓN DE LOS DATOS (sistema MONITOR)
Al visualizar los datos, se pueden controlar los valores instantáneos de funcionamiento del aparato
(que no se pueden modificar). Presionar dos veces el botón MODE (aparece un punto luminosos
intermitente a la derecha de la primera cifra). Presionar el botón STEP para visualizar todas las FASES
disponibles.
Notas
N
o
fase
Parámetro
Sistema acqua calda sanitaria
Temperatura de ida
Temperatura de retorno
Temperatura circuito sanitario
Temperatura externa (*)
Temperatura humos
Temperatura de ida programada o calculada
Valores a disposición del instalador
1
2
3
4
5
6
7,8
Valor
°
C
Valor
°
C
Valor
°
C
Valor
°
C
Valor
°
C
(*) Visualización del valor si se ha conectado una sonda (opcional)
No disponible
Con sonda externa OPCIONAL
Introducción del código de acceso
Para abandonar el programa VISUALIZACIÓN DE LOS DATOS hay que presionar una vez