https://www.lairdconnect.com/iot-devices/iot-sensors
23
© Copyright 2019 Laird. All Rights Reserved
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
7. Double-click the MQTT broker configuration. This brings up the customizable settings for this node. (Figure 36) On the
Connection tab, type the
MQTT broker’s address in Server and Port. (usually port 1883 is used for TCP and port 8883
is used for TCP/TLS)
Figure 36: Configuring MQTT Broker
8. Click the
Security Tab
. Enter user name and password for the MQTT broker.
9. Click
Update
to save parameters.
10. Click
Deploy
to update the node-RED application on the local node-RED server.
Note
: Whenever a change is made to the flow, you must click on the
Deploy
button to save the changes to the server. If
customizing the Flow, utilize the palette which contains a list of possible nodes located on the left-hand side of the
screen.
Once the MQTT client configuration is set and a MQTT connection is established, the communication links display a
connected status. Note that all the MQTT nodes on the flow share the same MQTT connection under-the-hood.