laguna Powerjet 1500 Скачать руководство пользователя страница 3

PUMP INSTALLATION INSTRUCTIONS

General Information

PowerJet pumps are designed to generate powerful water circulation that is essential for
the creation of fountains and waterfalls. Besides being pleasant to see, water flow con-
tributes to the oxygenation of pond water, which is beneficial to pond fish and plants.

The pump is designed to circulate clear water only and is not a pond filter.

The pump motor sits inside a uniquely-shaped cage that is designed to block out any
solids that could potentially clog the pump and fountain jets. This unique blocking fea-
ture ensures an extended period of reliable operation.

The pump must never be

used without its cage.

In order to prevent the pump from sucking dirt
directly from the pond bottom, we recommend
that you install it on an elevated surface that is
flat and level. It is recommended that you
secure the pump to a fixed base by using the
keyhole-shaped slots located at the bottom of
the cage, which is shaped to allow the fast
engaging/disengaging of the pump from the
base. (See Fig. 3)

Check that the information on the nameplate
(which is located on the pump) corresponds to
the power supply. The electrical installation
and wiring must comply with the safety standards in your area. If unsure, ask a quali-
fied electrician to do the wiring. The electrical cord must be protected against any
objects that may potentially damage it. The electrical receptacle/socket must be locat-
ed in a dry, protected and easily accessible place.

WARNING: Always unplug or disconnect all appliances in the
pond from the electrical supply before installing, repairing,
maintaining or handling the equipment in the water.

Important: To achieve the best pump operation, always use the
largest bore hose possible. Avoid sharp bends in the hosing;
gradual curves are preferred.

Installation:

(see Fig. 2)

Warning: Do not plug in the pump before it is correctly and fully installed.

1) Insert the Telescopic Riser Stem (8) into the relevant seat of the diverter (7).
2) Insert the Fountain Jet (10 or 11) on the top of the Telescopic Riser Stem (8).
3) Insert the Diverter (7) complete with the Telescopic Riser Stem (8) and Fountain

Jet (10 or 11) onto the pump output, ensuring that the "Click-Fit" coupling clicks
into place.

4) If installing an underwater filter, see 

Extending pump operation using a

PowerFlo Underwater Filter

below. If using the backwash feature to periodically

rinse the pump cage, see 

Pump Cage Backwash

.

5) Place the pump in the pond ensuring that it is completely immersed in water and

securely installed on a solid, level and elevated platform. If necessary, use the 
keyhole-shaped slots at the bottom of the pump to fasten it to a secure base. Use
extra care when engaging or disengaging the pump.

6) Adjust the height of the Fountain Jet (10 or 11) by moving the Telescopic Riser

Stem (8) up or down.

7) To further increase the height of the Fountain Jets, attach an optional Extension

Tube (sold separately, PT-645).

8) To use the additional outlet of the Diverter to transfer water to a waterfall, a

PowerClear UV Sterilizer or other equipment, connect a flexible hose (not included)
to the side outlet of the Diverter using a Click-Fit coupling. If using a Universal
Click-Fit coupling (13), cut it off at the required size by using a small hack saw in
order to allow the hose to fit properly and to achieve the best pump performance.

9) Water flow to the Fountain Jet or Waterfall Outlet can be adjusted separately

using the two control valves located on the sides of the Diverter (7).

Pump Operation

Once the pump is fully installed, it can be started by inserting the plug in the 
electrical receptacle/socket.

Opening and Closing the Pump Cage 

(see Fig. 4)

The upper and lower halves of the pump cage are fastened together by pivot pin 
fasteners. Using a standard flat screwdriver (5 mm to 8 mm), do the following:

To open the pump cage:

Gently turn the fastener counterclockwise by 1/4 to

release the pin.

To close the pump cage:

Gently press on the fastener and turn clockwise by 1/4 to

lock the pin.

Extending pump operation using a PowerFlo
Underwater Filter (sold separately)

To reduce the frequency of cleaning the pump and extending pump operation, you
can connect the main pump cage to a Laguna Underwater Filter (PT-500 or PT-505). In
additon to prolonging pump operation, installing a filter also improves the quality of
your pond water.

1) Open the pump cage by unlocking the pivot pin fasteners (Fig. 4)
2) The Pump Cage is equipped with a pre-scored section (Fig. 5) that must be cut out

with a suitable cutting tool

3) Insert a Remote Adapter (9) in the scored opening at the back of the Pump Cage
4) Close the cage, ensuring that the two halves are properly aligned and coupled,

and then lock them with the pivot pin fasteners (Fig. 4) on the unit

5) Connect the Pump Cage to the filter using flexible hosing (not included) attached

to the Click-Fit hose connector

Important: During pump operation, the Underwater Filter
must always be completely immersed in water to prevent air
from being sucked into the pump and damaging it. Also
ensure that the Pump Cage is securely locked before lifting
and operating the pump.

Pump Cage Backwash 

(see Fig. 6) 

The backwash system allows you to connect a garden hose to the pump in order to
partially clean off any dirt and debris resting on the surface of the pump cage. This
feature ensures the temporary restoration of water flow through the pump and also
brings new water to the pond. Use the Remote Adapter (9) and Garden Hose Adapter
(12) to connect a garden hose to the pump cage. Connect the other end of the hose
to a tap/water faucet. Disconnect the pump from the main power supply. Run the
water through the pump cage for at least 1 minute. Restore power to the pump.
Repeat if necessary.

NOTE: Add a suitable amount of Laguna Water Prep 
dechlorinator (sold separately, PT-860, PT-863) when adding
tap water to the pond.

Pump Maintenance

WARNING: Always unplug or disconnect all appliances in the
pond from the electrical supply before installing, repairing,
maintaining or handling the equipment in the water.

To avoid shortening the life of the pump, follow these simple maintenance 
procedures:

• Once a week, verify that the pump performance is satisfactory. If you detect a drop

in pump performance (a decrease in water flow to the fountain jet or waterfall),
first clean the Pump Cage, the Fountain Jet, the hosing, and the Diverter. If the
water flow is still not fully restored to its original performance, clean the Impeller,
Impeller Well and Impeller Cover (See maintenance procedure below)

3 Screws 

Fig.4

Fig.5

Fig.3

Garden Hose 

Adapter

Remote Adapter

PowerJet
Pump

Fig.6

PUMP CAGE BACKWASH
INSTALLATION

Garden Hose

Tap/Water
Faucet

FOUNTAIN PUMP KIT

For freshwater and submersible use only 

Read thoroughly prior to installation and operation

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To guard against injury, basic safety precau-
tions should be observed, including the following:

1.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

And  all  the important notices on the appliance before using the pump. Failure to
do so may result in loss of fish life and/or damage to this appliance.

2.

DANGER

– To avoid possible electric shock, special care should be taken since

water is employed in the use of pond equipment. For each of the following situa-
tions, do not attempt repairs yourself; return the appliance to the store where it
was purchased if still under warranty.

A. If the appliance shows any sign of abnormal water leakage or if RCD (or GFCI-

Ground Fault Current Interrupter) switches off, disconnect the power supply cord
from mains (main power supply) and remove pump from water.

B. Carefully examine the appliance after installation. It should not be plugged if

there is water on parts not intended to be wet.

C. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunc-

tioning or if it is dropped or damaged in any manner. The power cord of this 
appliance cannot be replaced; if the cord is damaged, the appliance should be dis-
carded. Never cut the cord.

3. Close supervision is necessary when any appliance is used by or near children.
4. To avoid injury, do not touch moving parts or hot parts.
5.

CAUTION

– Always unplug or disconnect all appliances in the pond from the 

electrical supply before placing hands in water, before putting on or taking off
parts and while the equipment is being installed, maintained or handled. When
inserting or removing the pump from the water, always pull out the main electri-
cal plug. Never yank the cord to pull the plug from outlet. Grasp the plug and pull
to disconnect. Always unplug an appliance from an outlet when not in use. Never
lift the pump by the cord. Use the unit handle.

6.

CAUTION

– This is a Pond Pump. This Pump Has Been Evaluated For Use With

Water Only. Do not use this pump for other than its intended use (i.e.: do not use
in swimming pools, bathrooms, etc.). The use of attachments not recommended or
sold by the appliance manufacturer may cause an unsafe condition.
• Do not use this pump in swimming pools or other situations where people are

immersed.

• This pump is suitable for use in water temperatures up to 35 °C.
• Do not use this pump with inflammable or drinkable liquids.

7. Do not install or store the appliance where it will be exposed to the weather or to

temperatures below freezing. Remove and store the pump in a sheltered place.
Shelter pump also from direct sunlight. The materials have high stability to 
sunlight but direct rays may overheat the motor and speed up insulator aging.

8.

IMPORTANT

- This pump can be operated only when the pump unit is 

correctly closed inside its Cage and after checking that the Cage is securely
locked by the fastening screws located on the unit handle. Make sure that the
pump is securely installed before operating it. Do not allow the pump to run dry.
The pump must be immersed in water completely. This pump must never operate
outside of water.

9. If an extension cord is necessary, ensure connection is watertight and dust proof.

A cord with proper rating should be used. A cord rated for less amperes or watts
than the appliance rating may overheat. Care should be taken to arrange the
cord so that it will not be tripped over or pulled. The connection should be 
carried out by a qualified electrical installer.

10.

IMPORTANT

– Supply through a Residual Current Device (RCD or Ground

Fault Current Interrupter) with rated residual current not exceeding 30 mA.

11.

WARNING

– Risk of electric shock – This pump is supplied with a grounding-

type or attachment plug. To reduce the risk of electric shock:
• be certain that it is connected only to a properly grounded, grounding-type

receptacle

• Use only on portable self-contained fountains no larger than 5 feet in any

dimension 

(FOR U.S.A. ONLY)

SAVE THESE INSTRUCTIONS FOR FUTURE

REFERENCE

Only the faithful observation of these installation, electrical and maintenance 
guidelines will ensure the safe and efficient use of this pump.

5

6

7

9

8

10

11

13

13

12

ADDITIONAL INSTRUCTIONS FOR U.K. ONLY

This product is designed to be permanently wired to the mains supply in a dry
weatherproof enclosure through a double pole switched fused spur which complies
to BS3676, fitted with a 3 Amp fuse. The installation must conform to the regula-
tions of the Local Electricity Authority which could include the use of plastic or
metal conduit to protect the cable. A 30 mA Residual Current Device ‘RCD’ must be
fitted to the mains supply.

WARNING - THIS APPLIANCE MUST BE EARTHED.

IMPORTANT - 

The wires in this mains lead are coloured in accordance with the 

following code:

Brown - Live       Blue - Neutral        Green/Yellow - Earth

The 

Brown

lead should be connected to the Live terminal, which may be marked

with an ‘L’ or coloured brown or red.
The 

Blue

lead should be connected to the Neutral terminal, which may be marked

with an ‘N’ or coloured blue or black.
The 

Green/Yellow

lead should be connected to the Earth terminal, which may be

marked with an ‘E’ or coloured green or yellow.

Fig.2

Closed

Closed

Open

Open

To Waterfall

To Fountain Jet

3

4

Содержание Powerjet 1500

Страница 1: ...ckel anzubringen Verwenden Sie diese Schablone um die genaue Position der Schrauben auf dem fest montierten Sockel zu bestimmen Beachten Sie dass der Sockel erh ht liegen und solide und sicher montier...

Страница 2: ...PT 443 PT 443 6 Pivot Pin Fasteners PT 447 PT 447 PT 447 PT 447 7 Diverter Valve PT 627 PT 628 PT 628 PT 628 8 Riser Stem PT 617 PT 617 PT 617 PT 617 9 Remote Adapter PT 609 PT 609 PT 609 PT 609 10 3...

Страница 3: ...lways unplug or disconnect all appliances in the pond from the electrical supply before installing repairing maintaining or handling the equipment in the water To avoid shortening the life of the pump...

Страница 4: ...it 2 Using a flathead screwdriver carefully lift out the impeller assembly 3 3 Clean all components in clean water only using a small non abrasive brush if necessary DO NOT USE DETERGENTS OR OTHER CH...

Страница 5: ...pareils loign s 9 et l adapteur du boyau d arrosage 12 pour raccorder un boyau d arrosage au bo tier de la pompe Raccorder l autre extr mit du boyau un robinet D brancher la pompe de l alimentation pr...

Страница 6: ...ever la couronne 3 avec soin l ext rieur 3 Nettoyer toutes les pi ces dans de l eau propre seulement avec une petite brosse non abrasive si n cessaire NE PAS UTILISER DE D TERGENTS NI D AUTRES NETTOYA...

Страница 7: ...ie den Netzstecker der Pumpe Lassen Sie mindestens eine Minute lang das Wasser laufen Schlie en Sie die Pumpe wieder ans Stromnetz an Falls erforderlich wiederholen Sie den Vorgang ANMERKUNG Bei Zuf h...

Страница 8: ...er Wartung erfordert jedoch extreme Sorgfalt Vermeiden Sie es die Achse fallen zu lassen oder sie zu starkem Druck auszusetzen da dies zu Spr ngen oder Haarrissen f hren kann die einen Achsbruch w hre...

Страница 9: ...e agua a trav s de la bomba y trae tambi n agua nueva al estanque Utilice el adaptador remoto 9 y el adaptador de manguera de jard n 12 para conectar la manguera de jard n a la jaula de la bomba Conec...

Страница 10: ...et 2000 7500 2400 9000 y 2900 11000 Ilus 1 1 Con un destornillador Phillips cabeza en cruz desatornille los cuatro tornillos de la tapa del impulsor 4 y qu tela 2 Con un destornillador de cabeza plana...

Страница 11: ...zum Ersatz der entsprechenden PowerJet Pumpe Diese Garantie erstreckt sich nicht auf PowerJet Pumpen die unsachgem er oder fahrl ssiger Verwendung Manipulationen oder deren Fl gelrad oder Fl gelradach...

Страница 12: ...tween 9 00 AM and 5 00 PM Eastern Time U S ONLY Toll Free Number 1 800 724 2436 Between 9 00 AM and 4 00 PM Eastern Time U K ONLY Helpline Number 01977 556622 Between 9 00 AM and 5 00 PM SERVICIO AUTO...

Отзывы: