Dake Corporation
1809 Industrial Park Dr
Grand Haven, MI 49417
976200-2, 976202-2
10
REV112019
a.
Failure to remove backlash may result in blade breakage and serious
injury.
9. While holding the blade against the pins tighten the spindle bolt securely.
10. Close blade cover and replace clear protective cover.
Blade Installation for a Non-Ferrous Head:
1. Open the clear protective cover and magnetically latched blade guard.
2. Clean spindle and flange faces, so there are no chips on the faces.
3. Remove part “b” using wrench “d” on shaft “c”.
4. Use hex wrench “e” to remove bolt “f”, which has left-handed threads.
5. Install blade on the spindle shaft shoulder, so the teeth are facing downwards, for
clockwise rotation.
6. Install blade flange. Make sure no to hit any machine parts with the carbide tips, this this
may affect the blade performance.
7. Screw the spindle bolt on by hand.
8. Holding the spindle shaft with the wrench, tighten the bolt securely.
9. Close and tighten blade cover and close clear protective cover.
Note: The blade pins may have been removed from your blade flange to allow easier blade
sizing and safety.
If you install the pins for a carbide or HSS blade backlash must be
removed from the blade while installing, however it is not recommended to reinstall these
pins.
See ferrous blade installation for backlash removal.