Using Compressed Air
DISCONNECT MACHINE FROM POWER!
For heavy duty users, it is recommended to use compressed air on a weekly basis to maintain
maximum filtration efficiency and longer life span of the filter.
REMOVING THE CANISTER FILTER
1.
Release the spring-loaded band clamp at the bottom of the canister filter and remove the
plastic bag.
Figure 7: Releasing filter clamp
2.
While supporting the canister filter assembly from the bottom, release the spring-loaded
band clamp from the top of the canister filter assembly.
Figure 8: Hold canister from bottom when releasing clamp
3.
Remove the (4) 3/16
”
x 3/4
”
sheet metal Philip bolts, (1)
5/16” x 3/4” hex bolt and
(1)
5/16”
x 7/8”
flat washer off the bottom of the canister filter.
4.
Remove the canister filter and carefully tilt the top of the canister filter assembly to clear the
paddle branches. Slightly bend the paddle branches to remove the canister filter.
Содержание CFLUX2
Страница 35: ...2 3 HP Mobile Dust Cyclone Manual 35 Parts Breakdown CFLUX 2 3 Fig 9 ...
Страница 36: ...2 3 HP Mobile Dust Cyclone Manual 36 Figure 10 Fan Motor Switch SECTION A Close up view ...
Страница 37: ...2 3 HP Mobile Dust Cyclone Manual 37 Figure 11 Cyclone Canister Barrel SECTION B Close up view ...
Страница 38: ...2 3 HP Mobile Dust Cyclone Manual 38 Figure 12 Panels Lock SECTION C Close up view ...
Страница 39: ...2 3 HP Mobile Dust Cyclone Manual 39 Figure 13 Barrel insert SECTION D Close up view 16H 16P ...
Страница 48: ...2 3 HP Mobile Dust Cyclone Manual 48 NOTES Ph 800 234 1976 www lagunatools com 100721 ...