Improper Line Voltage Have an electrician check voltage
Problem
Might be Caused By
Might Be Solved By
Heats, but not High
Enough
Thermostat turned
down
Raise thermostat
Dirty filter
Change filter
Slice valve closed
Open slice valves (instructions on
page 19)
Spa cover not in place
Reposition spa cover
Heats too much
Thermostat set too
high
Lower thermostat
Outside temperature
high to allow cooling
Add cold water
Lights Don’t Work
Bulb burned out
Replace bulb
Loose, dirty
connection
Check light connections
Jets Don’t Work
Air lock in pump(s)
Bleed Pump instructions on page 19
Slice valve(s) closed
Open slice valves (instructions on
page 19 )
Diverter valve closed
Rotate diverter until desired pressure
is achieved
Jet Closed
Rotate outer stainless rim of jet to
open
Dirty Filter
Change filter
Low Water Flow
Spa heating or filtering Normal spa function
Diverter valve position Rotate diverter valve to increase flow
Air valve closed
Rotate air valve to open
Dirty filter
Change filter
Slice valve(s) closed
Open slice valves (instructions on
page 19)
Improper Line Voltage Have an electrician check voltage
Troubleshooting Guide
If you do not see the solution to your problem , please call a
technical support associate at 877-722-4907 for assistance.
When making repairs to your spa, you should always
manually turn the GFCI “off” to eliminate risk of shock.