Topside Controls
Setting the Clock
Press and hold the “M” button for 6 seconds; the water temperature
will flash on the LED display followed by “
rtc
” (real time clock).
Use the “UP” arrow key to change the hours. Use the “DOWN”
arrow key to adjust the minutes. In the example shown, the clock
is set to 8:30 PM (20:30).
Press the “M” button to confirm the adjustment and move to the next parameter.
Setting the Start Time of the Filtration Cycle
Your LED will display “
fst
” (filter start time). The factory settings
start the filter cycle at 6 PM EST. To change the filter start time,
use the “UP” arrow button to adjust the hours and the “DOWN”
arrow button to adjust the minutes.
In this example, the filtration cycle is set to
begin at 6:00 PM (18:00), the factory setting.
Press the “M” key to confirm the changes.
Setting the Filter Duration
The LED will display “
ft1
”. Use the “UP” arrow button to adjust
the number of hours the spa will filter. The filtration cycles adjust
in hours only, not minutes. Pressing the “DOWN” button will not make any
adjustments.
In this example, the filtration cycle is set to run for 2 hours, which
is the factory setting.
Press the “M” button to move the next parameter.
Programming the Water Temperature Adjustment Allowance
The LED will display
“
Adj”.
Use the “UP” arrow button to raise
the temperature allowance. Use the “DOWN” arrow button to
decrease the water temperature allowance.
In this example, the manufacturer’s recommended settings are displayed. This
setting will maintain the pre-programmed water temperature and will maintain
the programmed settings of +/- 3°F before automatically heating the water.
The manufacturer recommended and factory settings will allow the water
temperature to fall 3°F before the heater automatically turns on to begin heating
the water and will automatically stop heating the water when the temperature
is no more than 3°F above the set temperature. With these settings, if your
water temperature is set to 99°F, the heater will automatically turn on when the
water temperature falls to 96°F and will automatically turn off when the water
temperature reaches no more than 102°F.
Press the “M” button to move to the next parameter.
The cycle will rotate back to “
rtc
”.
If you are satisfied with the changes, do not
press any buttons and allow the spa to exit programming mode. When the spa
has exited programming mode, the flashing “rtc” will be replaced by the water
temperature on the LED display.
rtC
20:30
Std
FSt
18:00
Std
Ft1
2:00
Std
28
Adj
-3F
Std
Содержание Spa