Labnet Prism Скачать руководство пользователя страница 12

To request certificates, please contact us at 

www.labnetlink.com.

Warranty/Disclaimer: 

Unless otherwise specified, all products are for research use only. Not intended 

for use in diagnostic or therapeutic procedures. Corning Life Sciences makes no claims regarding the 
performance of these products for clinical or diagnostic applications.

For additional product or technical information, visit 

www.corning.com/lifesciences

 or call 800.492.1110. 

Outside the United States, call +1.978.442.2200 or contact your local Corning sales office.

www.labnetlink.com

For a listing of trademarks, visit www.corning.com/clstrademarks. All other trademarks are the property of their respective owners. 
© 2021 Corning Incorporated. All rights reserved. 4/21 CLSLN-AN-1003DOC REV1

Corning Incorporated

Life Sciences

www.corning.com/lifesciences

NORTH AMERICA

t 800.492.1110 
t 978.442.2200

ASIA/PACIFIC
Australia/New Zealand

t 61 427286832

Chinese Mainland

t 86 21 3338 4338

India

 

t 91 124 4604000

Japan

t 81 3-3586 1996

Korea

t 82 2-796-9500

Singapore

t 65 6572-9740

Taiwan

t 886 2-2716-0338

EUROPE

[email protected] 
[email protected]

LATIN AMERICA

[email protected]

Brazil

t 55 (11) 3089-7400

Mexico

t (52-81) 8158-8400

Содержание Prism

Страница 1: ...Prism Microcentrifuge Instruction Manual Catalog Numbers C2500 C2500 230V This manual is available in additional languages at www labnetlink com...

Страница 2: ...sories 3 6 2 Rotor Maintenance 4 6 3 Removing and Installing the Angle Rotor 4 6 4 Loading the Rotor 4 6 5 Overloading Rotors 4 7 0 Operation 5 7 1 Attaching Rotor Lid 5 7 2 Closing the Lid 5 7 3 Lid...

Страница 3: ...equipment Never centrifuge flammable explosive or corrosive materials Never centrifuge hazardous materials outside of a hood or proper containment facility Always load the rotor symmetrically Each tu...

Страница 4: ...nual 1 each Warranty card 1 each Power cord 1 each 5 0 Installation The centrifuge should be installed on a rigid even surface such as a stable laboratory bench countertop etc To guarantee sufficient...

Страница 5: ...ncluded Cat No AR110 Strip Spin Adapter Cat No C2400 SS Tubes Accepted 0 2 mL tubes or 8 x 0 2 mL strips Maximum Speed 15 000 rpm Centrifuge Radius Range 4 32 cm to 5 33 cm RCF G value Range 10 874 x...

Страница 6: ...otor wrench 6 4 Loading the Rotor Tubes to be loaded should be filled equally by eye The difference in the weight between the tubes should not exceed 0 1 gram Tubes should always be loaded so that the...

Страница 7: ...ARNING Do not attempt to open the lid of any centrifuge until the rotor has come to a complete stop In the event of a power failure or malfunction it may be necessary to open the lid manually 1 Discon...

Страница 8: ...ousing rotor chamber rotor and rotor accessories clean All parts should be wiped down periodically with a soft cloth For more thorough cleaning use a neutral cleaning agent pH between 6 and 8 applied...

Страница 9: ...and or time bAL Error Message Indicates imbalance Tubes not inserted symmetrically in rotor holes Load tubes symmetrically see Section 3 4 on Loading the rotor Sample liquid in tubes not balanced Make...

Страница 10: ...e has an automatic g force conversion program so g values are automatically calculated and can be displayed on the control panel for this centrifuging radius If adapters or smaller tubes are used the...

Страница 11: ...or contact your local support office Corning s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions Products rec...

Страница 12: ...r local Corning sales office www labnetlink com For a listing of trademarks visit www corning com clstrademarks All other trademarks are the property of their respective owners 2021 Corning Incorporat...

Отзывы: