Labnet Prism Скачать руководство пользователя страница 11

  Instruction Manual        | 

         9

 11.0  Limited  Warranty

Corning Incorporated (Corning) warrants that this product will be free from defects in material 
and workmanship for a period of one (1) year from date of purchase. CORNING DISCLAIMS ALL 
OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s sole obligation shall be 
to repair or replace, at its option, any product or part thereof that proves defective in material or 
workmanship within the warranty period, provided the purchaser notifies Corning of any such defect. 
Corning is not liable for any incidental or consequential damages, commercial loss or any other damages 
from the use of this product.

This warranty is valid only if the product is used for its intended purpose and within the guidelines 
specified in the supplied instruction manual. This warranty does not cover damage caused by accident, 
neglect, misuse, improper service, natural forces or other causes not arising from defects in original 
material or workmanship. This warranty does not cover motor brushes, fuses, light bulbs, batteries or 
damage to paint or finish. Claims for transit damage should be filed with the transportation carrier.

In the event this product fails within the specified period of time because of a defect in material or 
workmanship, contact Corning Customer Service at: USA/Canada 1.800.492.1110, outside the U.S. 
+1.978.442.2200, visit 

www.corning.com/lifesciences

, or contact your local support office.

Corning’s Customer Service team will help arrange local service where available or coordinate a return 
authorization number and shipping instructions. Products received without proper authorization will 
be returned. All items returned for service should be sent postage prepaid in the original packaging or 
other suitable carton, padded to avoid damage. Corning will not be responsible for damage incurred by 
improper packaging. Corning may elect for onsite service for larger equipment.

Some states do not allow limitation on the length of implied warranties or the exclusion or limitation 
of incidental or consequential damages. This warranty gives you specific legal rights. You may have other 
rights which vary from state to state.

No individual may accept for, or on behalf of Corning, any other obligation of liability, or extend the 
period of this warranty.

For your reference, make a note of the serial and model number, date of purchase, and supplier here.

Serial No.  __________________________________________ 

Date Purchased  _______________________________________

Model No.  _________________________________________ Supplier _____________________________________________

12.0  Equipment Disposal

According to Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 
on waste electrical and electronic equipment (WEEE), this product is marked with the crossed-out 
wheeled bin and must not be disposed of with domestic waste. 

Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and 
electrical equipment (WEEE) provided with the products and available at 

www.corning.com/weee

.

 

Содержание Prism

Страница 1: ...Prism Microcentrifuge Instruction Manual Catalog Numbers C2500 C2500 230V This manual is available in additional languages at www labnetlink com...

Страница 2: ...sories 3 6 2 Rotor Maintenance 4 6 3 Removing and Installing the Angle Rotor 4 6 4 Loading the Rotor 4 6 5 Overloading Rotors 4 7 0 Operation 5 7 1 Attaching Rotor Lid 5 7 2 Closing the Lid 5 7 3 Lid...

Страница 3: ...equipment Never centrifuge flammable explosive or corrosive materials Never centrifuge hazardous materials outside of a hood or proper containment facility Always load the rotor symmetrically Each tu...

Страница 4: ...nual 1 each Warranty card 1 each Power cord 1 each 5 0 Installation The centrifuge should be installed on a rigid even surface such as a stable laboratory bench countertop etc To guarantee sufficient...

Страница 5: ...ncluded Cat No AR110 Strip Spin Adapter Cat No C2400 SS Tubes Accepted 0 2 mL tubes or 8 x 0 2 mL strips Maximum Speed 15 000 rpm Centrifuge Radius Range 4 32 cm to 5 33 cm RCF G value Range 10 874 x...

Страница 6: ...otor wrench 6 4 Loading the Rotor Tubes to be loaded should be filled equally by eye The difference in the weight between the tubes should not exceed 0 1 gram Tubes should always be loaded so that the...

Страница 7: ...ARNING Do not attempt to open the lid of any centrifuge until the rotor has come to a complete stop In the event of a power failure or malfunction it may be necessary to open the lid manually 1 Discon...

Страница 8: ...ousing rotor chamber rotor and rotor accessories clean All parts should be wiped down periodically with a soft cloth For more thorough cleaning use a neutral cleaning agent pH between 6 and 8 applied...

Страница 9: ...and or time bAL Error Message Indicates imbalance Tubes not inserted symmetrically in rotor holes Load tubes symmetrically see Section 3 4 on Loading the rotor Sample liquid in tubes not balanced Make...

Страница 10: ...e has an automatic g force conversion program so g values are automatically calculated and can be displayed on the control panel for this centrifuging radius If adapters or smaller tubes are used the...

Страница 11: ...or contact your local support office Corning s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions Products rec...

Страница 12: ...r local Corning sales office www labnetlink com For a listing of trademarks visit www corning com clstrademarks All other trademarks are the property of their respective owners 2021 Corning Incorporat...

Отзывы: