LM-3605 Dynamic Label Applicator
USERS MANUAL
Page 45
Made in the U.S.A.
© 2019 LABELMILL
12/01/2019 Model LM3605
DESCRIPTION OF I/O
LEGEND
24V OPT:
24V OPTO INPUT WITH INTERNAL 24V COMMON
OH:
HIGH CURRENT OUTPUT Rated @ 500ma
All user inputs and outputs are
“SINKING”
type. Example in order for a status light to illuminate for “Run Status
Ok” the light should be wired between pins #2 & #4 on the
“Light Bar/Aux.”
Connector.
Status display legend.
INPUTS
OUTPUTS
S
P
H
Y
A
F
V
T
SMART
TAMP
PRODUCT
SENSOR
HEAD UP
TAMP
SENSOR
AUX OUT
#1
AIR ASSIST
SOL
FLAG
SOL
VACUUM
SOL
TAMP
SOL
P0.0
PAPER END INPUT
0=ON
P0.1
RIBBON END INPUT
0=ON
P0.2
PRINER ERROR INPUT
0=ON
P0.3
RIBBON NEAR END INPUT
0=ON
P0.4
PRINT END INPUT
0=ON
P0.5
ON-LINE INPUT
0=ON
P0.6
REPRINT OUTPUT
0=ON
P0.7
PRINT OUTPUT
0=ON
P1.3
RED LIGHT ON (GREEN OFF)
1=ON
P1.4
YELLOW LIGHT ON
1=ON
P1.5
LOW LABEL INPUT
0=ON
P1.6
TAKEUP MOTOR OUT
0=ON
P1.7
AUX INPUT (DISABLE)
0=ON
P2.0
NOT APPLICABLE
0=ON
P2.1
NOT APPLICABLE
0=ON
P2.4
VACCUM SOL OUT
0=ON
P2.5
AIR ASSIST OUT
0=ON
P2.6
ROUND MODULE OUT
0=ON
P2.7
FLAG SOL OUT
0=ON
P3.4
TRIGGER INPUT
0=ON
P3.5
HEAD UP SWITCH INPUT
0=ON
P3.6
SMART TAMP INPUT
0=ON
P3.7
PRE-PRINT START INPUT
0=ON
The bit not listed above are used for serial clock data, RS232, and internal functions
3-17